[504] PULSE MAKE/BREAK RATIO
Allows the ability to change the value of pulses per second and the duration of the
make/break time. This will only affect rotary dial trunks.
No
Item
Description
0
MAKE/BREAK RATIO
Make/Break ratio of dial pulse (01-99)
1
PULSE PER SECOND
Number of dial pulses per second (10 or 20)
DEFAULT DATA
MAKE/BREAK: 33 MAKE
PULSES PER SECOND: 10 PPS
ACTION
DISPLAY
1) Press Transfer button and enter 504.
Display shows:
MAKE/BREAK RATIO
33 MAKE
2) Dial 0 or 1 for option.
OR
PULSE PER SECOND
10 PPS
_
Press Volume button for selection and press Right Soft
button to move cursor.
3) Dial new value.
System returns to step 2.
PULSE PER SECOND
10 PPS
20
4) Press Transfer button to save and exit.
OR
Press Speaker button to advance to next MMC.