OfficeServ 7000 Series Call Server Programming Manual
© SAMSUNG Electronics Co., Ltd.
2-321
[804] SYS I/O MODE
This is the program to designate the MODEM port of the system.
SERVICE: Service type
Number
Service Type
Description
00
NOT USE
Not using
01
IT
IT, Remote Programming
BAUD RATE: Transmission time
Option
Setting Value
0
4800 bps
1
9600 bps
2
19200 bps
3
38400 bps
CHAR LENGTH: Length of the characters
Option
Setting Value
7
7 bits
8
8 bits
PARITY: Parity bit
Option
Setting Value
0
NONE
1
ODD
2
EVEN
RETRY COUNT: Number of retry attempts
(01~99)
STOP BIT: Stop bit
Option
Setting Value
1
1 bit
2
2 bit