OfficeServ 7000 Series Call Server Programming Manual
© SAMSUNG Electronics Co., Ltd.
2-359
(Continued)
No
Parameter
Description
14
IP-UMS SERVER
Specify an IP UMS SERVER IP address.
(This option may not be available in certain OfficeServ models.)
15
IP-UMS PORT
Specify an IP UMS SERVER port.
(This option may not be available in certain OfficeServ models.)
16
IP-IVR SERVER
Specify an IP IVR SERVER IP address.
(This option may not be available in certain OfficeServ models.)
17
IP-IVR PORT
Specify an IP IVR SERVER port.
(This option may not be available in certain OfficeServ models.)
18
MASTER/SLAVE IP
Specify an Slave (extension Rack) IP address in OS7030.
(This option may not be available in certain OfficeServ models.)
19
MMS PORT
IP address of NMS TRAP Server
(This option may not be available in certain OfficeServ models.)
21
NMS TRAP SERVER
IP address of NMS TRAP Server
(This option may not be available in certain OfficeServ models.)
22
CTI SERVER ADDR
IP address of CTI Server
25
NEWS ADDRESS
IP address of News Server
26
EMAIL SERVER
Specify an EMAIL SERVER IP address.
(This option may not be available in certain OfficeServ models.)
27
MMS SERVER ADDR
Specify an MMS SERVER IP address.
(This option may not be available in certain OfficeServ models.)
28
MMS WEB SERVER
Specify an MMS WEB SERVER IP address.
(This option may not be available in certain OfficeServ models.)
29
IMPS SERVER ADDR Specify an IMPS SER SERVER IP address.
(This option may not be available in certain OfficeServ models.)
30
QoS CHECK
SERVER
Specify a QoS CHECK SERVER IP address.
(This option may not be available in certain OfficeServ models.)
LAN PARAMETERS
- The first three parameters: SYSTEM IP ADDR, SYSTEM GATEWAY, and
SYSTEM NET MASK are stored separately from the main system database
and thus will not be defaulted when MMC811 ‘CLEAR MEMORY’ is performed.
Furthermore, any changes to these parameters will not be applied until the MP
card is reset.
- When changing any IP address/value, three digits must be entered for each
(octet) field. For example 192.168.1.10 should be entered as: 192 168 001 010.
CONDITIONS
This MMC must be used if there are ITP phones and/or MGI cards on the system.
After changing LAN parameters, restart the system to apply the new settings.
Summary of Contents for OfficeServ 7000 Series
Page 1: ...GABD 000264 Ed 02 OfficeServ 7000 Series Call Server Programming Manual ...
Page 6: ...Revision History IV SAMSUNG Electronics Co Ltd This page is intentionally left blank ...
Page 18: ...TABLE OF CONTENTS XVI SAMSUNG Electronics Co Ltd This page is intentionally left blank ...
Page 82: ...CHAPTER 2 MMC Programming 2 44 SAMSUNG Electronics Co Ltd RELATED ITEMS NONE ...
Page 486: ...ABBREVIATION VI SAMSUNG Electronics Co Ltd This page is intentionally left blank ...