OfficeServ 7000 Series Call Server Programming Manual
© SAMSUNG Electronics Co., Ltd.
2-391
[840] IP PHONE INFORMATION
This MMC provides a means to register IP phones with the OfficeServ 7000 Series system.
During registration, the IP and MAC addresses are also registered. The User ID and
Password must match the table entry in this MMC for the IP phone to be registered.
The system default phone numbers are 3201~3299 and default User IDs match the default
station numbers. The system default password is 1234. IP phones must be individually
programmed with a User ID and Password in order to register with the system.
No
Option
Description
Default
00
USER ID
This is the ID the IP phone must match to register
with the OfficeServ 7000 Series system.
(alphanumeric)
To register IP phone in PnP mode (plug and play),
the MAC address of IP phone has to be entered in
USER ID option. And then IP phone has to do
factory reset.
First 99 IP phones
are 3201~3299,
others are EMPTY.
01
USER PSWD
This is the password the IP phone must have to
register with the OfficeServ 7000 Series system.
(alphanumeric)
‘1234’
02
IP ADDR
This is the IP address of the IP phone when
registered with the system. (Read only)
0.0.0.0.
03
MAC ADDR
This is MAC address of the IP phone when
registered with the system. (Read only)
FFFFFFFFFFFF
04
SIG PORT
This is the IP UDP port of the IP phone when
registered with the system. (Read only) This
information will be needed when traversing NAT
routers, firewalls, etc.
6000
05
VOICE PORT
This is the IP RTP port of the IP phone when
registered with the system. (Read only) This
information will be needed when traversing NAT
routers, firewalls, etc.
9000
07
DSP TYPE
This selects which CODEC this phone’s DSP will use.
G.729A (low bandwidth) or G.711 (high bandwidth).
This data uses IP phone to IP phone connection
only; others follow MGI CODEC type.
G.729A
08
PHONE TYPE
This is the type of IP phone used, SAMSUNG or SIP
(future). Use SAMSUNG.
SAMSUNG
09
REGIST CLR
This is used to clear the registration of a particular
IP phone. This is similar to unplugging and plugging
in the phone and is useful for maintenance.
NO
10
FRAME
COUNT
This value determines the transmission interval time
of VoIP packets generated by the IP phone.
This data uses MMC 841 ITP DSP PARA DOWN =
PHONE DATA only. The range is 10~40 ms.
20 ms
Summary of Contents for OfficeServ 7000 Series
Page 1: ...GABD 000264 Ed 02 OfficeServ 7000 Series Call Server Programming Manual ...
Page 6: ...Revision History IV SAMSUNG Electronics Co Ltd This page is intentionally left blank ...
Page 18: ...TABLE OF CONTENTS XVI SAMSUNG Electronics Co Ltd This page is intentionally left blank ...
Page 82: ...CHAPTER 2 MMC Programming 2 44 SAMSUNG Electronics Co Ltd RELATED ITEMS NONE ...
Page 486: ...ABBREVIATION VI SAMSUNG Electronics Co Ltd This page is intentionally left blank ...