OfficeServ 7000 Series Call Server Programming Manual
© SAMSUNG Electronics Co., Ltd.
2-423
[854] DIAGNOSTIC TIME
Provides a means to set the Diagnostic Time. The system diagnostics tests include memory
audits, internal loopback tests on digital trunks, and DSP, AA DSP tests. Additional tests
include CODEC tests on analogue trunk and station cards and tone tests. If the diagnostics
cannot complete the tests because of system traffic, the system will abort the tests and retry
during the next programmed diagnostic time. It is recommended to assign the diagnostic
time during non-peak traffic periods.
DEFAULT DATA
NO DIAGNOSTIC TIME SET
ACTION
DISPLAY
1) Press Transfer button and enter 854.
Display shows:
DIAGNOSTIC TIME
SUN::
2) Enter weekday number.
(0: Sun, 1: Mon, …, 6: Sat)
DIAGNOSTIC TIME
SUN:_:
OR
Press Volume button to make selection and press
Right Soft button to move cursor.
3) Enter hour (24-hour clock) via the dial keypad.
Cursor will advance to next entry.
DIAGNOSTIC TIME
SUN:23:_
4) Enter minutes (24-hour clock) via the dial keypad.
Cursor will return to step 2.
DIAGNOSTIC TIME
SUN:23:30
5) Press Transfer button to save and exit.
OR
Press Speaker button to advance to next MMC.
RELATED ITEMS
MMC 851
ALARM REPORTING
MMC 852
SYSTEM ALARM ASSIGNMENTS
MMC 853
MAINTENANCE BUSY
Summary of Contents for OfficeServ 7000 Series
Page 1: ...GABD 000264 Ed 02 OfficeServ 7000 Series Call Server Programming Manual ...
Page 6: ...Revision History IV SAMSUNG Electronics Co Ltd This page is intentionally left blank ...
Page 18: ...TABLE OF CONTENTS XVI SAMSUNG Electronics Co Ltd This page is intentionally left blank ...
Page 82: ...CHAPTER 2 MMC Programming 2 44 SAMSUNG Electronics Co Ltd RELATED ITEMS NONE ...
Page 486: ...ABBREVIATION VI SAMSUNG Electronics Co Ltd This page is intentionally left blank ...