OfficeServ 7000 Series Call Server Programming Manual
© SAMSUNG Electronics Co., Ltd.
2-437
[865] FAN POWER CONTROL
This MMC is the program that can control power of FAN located in the cabinet.
CONDITIONS
When using the MMC [865]
This MMC is only shown in OfficeServ 7400 because OfficeServ 7400 only
supports FAN POWER CONTROL.
DEFAULT DATA
NONE
ACTION
DISPLAY
1) Press Transfer button and enter 865.
Display shows:
FAN PWR CONTROL
CABINET1 FAN:OFF
2) Select the cabinet number. (1~3)
OR
FAN PWR CONTROL
CABINET1 FAN:OFF
Press Volume button to select and press Right Soft
button to move cursor.
3) Enter OFF if power off fan or ON if power on.
OR
FAN PWR CONTROL
CABINET1 FAN:ON
Press Volume button to select and press Right Soft
button to store.
4) Press Transfer button to save and exit.
OR
Press Speaker button to advance to next MMC.
RELATED ITEMS
NONE