30
STATION TIMERS
Each station can have five timers customized for them to accommodate station
users with individual work habits. These timers are as follows:
NO ANS FWD
No Answer Forward
This is the amount of time a call will ring at a station before it forwards to the
Forward No Answer destination. The default is 15 seconds and the range is 000 to
250 seconds. Make sure that this timer is not set to a greater value than the trans-
fer recall timer or transferred calls will not forward.
DTMF DUR.
DTMF Duration
This is the duration of DTMF tones sent to an analog voice mail port. The default
duration is 100 milliseconds and the range is 0100 to 9900 milliseconds.
F-DGT DELY
First Digit Delay
This is the time the system will wait before sending DTMF digits to a voice mail
port. The default time is 600 milliseconds and the range is from 100 to 9900 mil-
liseconds.
OFFHK SEL.
Off Hook Select
This timer controls the delay between going off hook (lifting the handset) and the
off hook select destination being called.The default duration is 10 seconds and the
range is from 000 to 250 seconds.
EFWD DELAY
External Forward Delay
This is the time that a station will ring before a call forwards to the external call for-
ward destination. The default duration is 10 seconds and the range is 1 second to
250 seconds.
Open customer programming and follow the instructions below.
PROGRAM KEYS
KEYPAD
- Used to set timer values.
UP
&
DOWN
- Used to select extension number.
SPK/RLS
- Save data and advance to next program.
ACTION
DISPLAY
1. Press
TRSF
and then dial
502
[201] NO ANS FWD
Display shows
010 SEC
System_Administration_Guide.qxp 4/30/2007 12:56 PM Page 37
Summary of Contents for OfficeServ 7000 Series
Page 5: ...System_Administration_Guide qxp 4 30 2007 12 56 PM Page 4...
Page 15: ...System_Administration_Guide qxp 4 30 2007 12 56 PM Page 14...
Page 17: ...System_Administration_Guide qxp 4 30 2007 12 56 PM Page 16...
Page 45: ...N O T E S System_Administration_Guide qxp 4 30 2007 12 56 PM Page 44...