CHAPTER 2. MMC Programming
2-160
© SAMSUNG Electronics Co., Ltd.
[434] CONNECTION STATUS
This read-only MMC will confirm the connection status of stations or trunks. Display
status displays the status of a station or trunk at the time requested. If a conference is in
progress with the selected trunk or station, the display will show one of the conference
parties and an arrow (
). The technician or system administrator can then display the other
parties in the conference. If a station or trunk is in an idle state, the display will show
‘IDLE’. If the station or trunk selected is not a valid selection, the display will show
‘INVALID DATA’. If the station or trunk is made busy by the CPU, the display will show
‘MADE BUSY’. If the station is in busy state with no other connection, the display will
show ‘BUSY’ only.
DEFAULT DATA
NONE
ACTION
DISPLAY
Display trunk connection status
1) Press Transfer button and enter 434.
DISPLAY STATUS
201 IDLE
2) Enter station or trunk number.
Display show connection status:
DISPLAY STATUS
702 227
3) Enter another station or trunk.
OR
DISPLAY STATUS
702 227
Press Transfer button to exit.
Display station connection status
1) Press Transfer button and enter 434.
DISPLAY STATUS
201 IDLE
2) Enter station or trunk number.
Display show connection status.
DISPLAY STATUS
235 715
3) Enter another station or trunk.
OR
DISPLAY STATUS
235 715
Press Transfer button to exit.
Summary of Contents for OfficeServ 7000 Series
Page 1: ...GABD 000264 Ed 02 OfficeServ 7000 Series Call Server Programming Manual ...
Page 6: ...Revision History IV SAMSUNG Electronics Co Ltd This page is intentionally left blank ...
Page 18: ...TABLE OF CONTENTS XVI SAMSUNG Electronics Co Ltd This page is intentionally left blank ...
Page 82: ...CHAPTER 2 MMC Programming 2 44 SAMSUNG Electronics Co Ltd RELATED ITEMS NONE ...
Page 486: ...ABBREVIATION VI SAMSUNG Electronics Co Ltd This page is intentionally left blank ...