OfficeServ 7100
PROGRAMMING
TECHNICAL MANUAL
PART 2 APRIL 2007
MMC: 500
SYSTEM-WIDE COUNTERS
DESCRIPTION:
Used to set the values of the system counters. The counters are listed below with a
brief description of each.
0 ALARM REM. CNTER
The number of times that an alarm reminder will ring a
station before cancelling. RANGE = 1-99. (Also used
for wake up calls).
1 AUTO RDL COUNTER
The number of times the system will redial an outside
number after the auto redial feature has been
activated. RANGE = 1-99.
2 DISA CALL CNTER
Sets the maximum number of intercom calls that can
be made after accessing a DISA line. RANGE = 1-99.
3 DISA LOCK CNTER
Number of attempts the system will allow to incorrectly
access a DISA line before locking out the DISA line.
RANGE =1-99
4 NEW CALL COUNTER
Number of times the system will allow a user to signal
New Call on a C.O. line during one call.
RANGE = 1-99.
5 UCDS VISUAL ALARM
Used to set the Visual alarm threshold. It is triggered
when the number of calls waiting to be answered in
the UCD group reaches this value. The SP key will
flash when this number of calls is queued to the UCD
group. RANGE = 0-25.
6 UCDS AUDIO ALARM
Used to set the Audio alarm threshold. It is triggered
when the number of calls waiting to be answered in
the UCD group reaches this value. The SP key will
flash and the phone will ring when this number of calls
is queued to the UCD group. RANGE = 0-25.
7 UCD CS LEVEL 1
Provides call wait indication level 1 if number of calls
waiting to be answered in UCD group reaches this
value. CS keys will flash amber when this number of
calls is queued to the UCD group. RANGE = 0-25.
Home Page