3.3.1.4 Abnormal SIO Operation
The procedure for resolving the problem caused by system UART port operation of cabinet
when MP10/11 board is used is as follows:
No
Yes
No
Yes
Replace U20.
- Check MMC.
- Check the S/W version.
- Check if other functions operate
properly.
- Replace CPU(U1).
Start
Check the connection up to RJ-45.
Is TXD of U20(MAX3232)
generated?
Is signal generated from
E4(UART_TX) PIN of
MP10/11 CPU?