1.2.2 SYSTEM CAPACITIES
When configuring a system to meet your requirements, select the appropriate number of interface cards listed in
Part 2 of this book to support the various types of switches, trunks, stations, voice mail and miscellaneous func-
tions. Combine both the physical ports of the main cabinet with the virtual ports in virtual cabinets 2 through 5
to build a system as required. Your authorized Samsung Installation and Service Company has special knowledge
and training to do this.
The following table indicates the maximum number of each circuit type or device available in the OfficeServ
7100. The system architecture is designed to be extremely flexible so as to provide a myriad of configurations.
However, it is impossible to accommodate all the maximum numbers of each station or trunk type into one sys-
tem.
1.5
Stations
Wireless Handsets
24
Standard SIP Phones
Analog Phones
24
Digital Phones
Samsung IP Phones / Softphone
32
Voice Mail
4
COMBINED TOTAL OF ALL STATIONS TYPES CANNOT EXCEED: 32
Trunks
Standard SIP Trunks
24
Standard H.323 Trunks
Analog Trunks
20
Digital Trunks T1/PRI
23
Networking Trunks
24
COMBINED TOTAL OF ALL TRUNK TYPES CANNOT EXCEED: 24
MAXIMUM ST VOICEMAIL
60
Other Devices
Networking Nodes
I
SPNet via QSig
I
SPNet via IP
99
99
Uses available T1/PRI card slots.
Limited by IP Address Table,
MMC 820.
Media Gateway Ports
24
Required to connect an IP phone to a
TDM device including paging and back-
ground music and ports used for net-
working or trunking. (MGI-16 +
Embedded)
Mobile Extensions (MOBEX)
60
Conferencing Circuits
I
5 Party Add-On
I
Unsupervised
I
Barge-In
I
Call Record
I
AME
6
6
6
6
6
Six Conference Circuits to be shared by all
of these features.
Common Resources
I
DTMF Receivers/Senders
I
Analog Caller ID Senders/Receivers
I
External Music On Hold (MOH)
I
Voicemail Ports
I
Executive MOBEX Resources
I
Media Proxy Service Channels
8
8
1
4
8
8
4 on MCP plus 12 on optional MFM
All on MCP
Optional RCM2 daughter board
Requires CPE and optional MIS
Provides IP to IP conversations without
using MGI channels
Paging
I
Audio Output
I
Internal Zones
I
External Zones
1
5
4
1 on MP10a card
(32 members each internal zone)
Requires customer provided
equipment.
Maximum BHCA (Busy Hour Call Attempts) (MP10a)
1,600
(0.45 erl, 90 sec)
Home Page