background image

 

OfficeServ 7200 System Description 

© SAMSUNG Electronics Co., Ltd. 

2-23

 

Specification 

The 4HTRK provides 4 trunk line ports. 

 

Front View of the 4HTRK 

The front view of the 4HTRK is shown in the figure below. 

 

Figure 2.13    Front View of the 4HTRK 

 

The components on the front panel of the 4HTRK have the functions below: 

 

Table 2.16    Ports and LEDs of the 4HTRK 

Ports, LEDs 

Functions 

P1~4 

Trunk Line Port 

P1~4 RD LED 

R/D Port Operation Status 

- Off: Not being used 

- On: The trunk line is being used 

- Blink: The RD mode is being configured 

P1~4 EM LED 

E & M Port Operation Status 

- Off: Not being used 

- On: The trunk line is being used 

- Blink: The E & M mode is being configured 

P1~4 DD LED 

DID Port Operation Status 

- Off: Not being used 

- On: The trunk line is being used 

- Blink: The DID mode is being configured 

 

 

 

4HTRK 

P1 

P2 

P3 

P4 

RD 

EM 

 

DD 

RD 

EM 

 

DD 

P1 

P2 

P3 

P4 

Summary of Contents for OfficeServ 7200

Page 1: ...GABD 000038 Ed 05 OfficeServ 7200 System Description...

Page 2: ...rademarks of their respective companies This manual should be read and used as a guideline for properly installing and operating the product This manual may be changed for the system improvement stand...

Page 3: ...s chapter describes the hardware feature cabinet configuration board function and board pattern of OfficeServ 7200 In addition this chapter also describes various terminals wireless LAN equipments and...

Page 4: ...s that the reader should follow in order to avoid personal injury or fatality NOTE Indicates additional information as a reference Reference OfficeServ 7200 Installation Manual Describes the necessary...

Page 5: ...I2 LIM P and SVMi 20E board Complementing wireless LAN base station Chapter 3 Adding external rectifier Modifying system circuit capacity ISDN transmission attribute and VDSL signal method Modifying s...

Page 6: ...Error Use the Home tab to apply 8 1 to the text that you want to appear here IV SAMSUNG Electronics Co Ltd This page is intentionally left blank...

Page 7: ...1 2 1 Interfaces between the Sub Modules 1 6 1 2 2 Interfaces between the VoIP Elements 1 8 1 3 Programming 1 9 CHAPTER 2 Hardware of the OfficeServ 7200 2 1 2 1 Hardware Features 2 1 2 2 Cabinet Con...

Page 8: ...1 3 1 System Capacity 3 1 3 1 1 Trunk Line Capacity 3 5 3 1 2 Station Subscriber Line Capacity 3 6 3 2 Electrical Specifications 3 7 3 2 1 Signal Specifications 3 7 3 2 2 Transmission Characteristics...

Page 9: ...4 2 5 Call Log 4 4 4 2 6 Forward Busy 4 4 4 2 7 Forward No Answer 4 4 4 2 8 Parallel Forking 4 4 4 3 Data Functions 4 5 4 3 1 Switches 4 5 4 3 2 Routers 4 6 4 3 3 Security 4 8 4 3 4 Data Applications...

Page 10: ...of the UNI Voice Subscriber 2 19 Figure 2 10 Front View of the 8TRK 2 20 Figure 2 11 Front View of the 8TRK2 2 21 Figure 2 12 Front View of the 16TRK 2 22 Figure 2 13 Front View of the 4HTRK 2 23 Fig...

Page 11: ...of the MP20S 2 11 Table 2 7 Specification of the MP20S 2 12 Table 2 8 Ports and LEDs of the MP20S 2 13 Table 2 9 Ports and LEDs of the LCP 2 14 Table 2 10 Ports and LEDs of the TEPRIa 2 16 Table 2 11...

Page 12: ...acteristics of the T1 Trunk Line 3 7 Table 3 10 Electrical Characteristics of the E1 Trunk Line 3 8 Table 3 11 Electrical Characteristics of the BRI Trunk Line 3 8 Table 3 12 Electrical Characteristic...

Page 13: ...hones IP phones mobile phones and PC servers 1 1 1 Major Functions The major functions and features of the OfficeServ 7200 are described below Integrated Communication Environment The OfficeServ 7200...

Page 14: ...s handoff and QoS Because the OfficeServ 7200 uses a wireless LAN base station it allows the users to make wire wireless voice data communications or access the Internet without establishing the LAN A...

Page 15: ...a basic cabinet mounted in a 19 inch rack The Main Control Processor MP20S is installed into the basic cabinet and manages the basic cabinet of OfficeServ 7200 The other components are various interf...

Page 16: ...f 4TRM option board is mounted on the UNI board it operates as a voice trunk board and supports an analogue trunk line and provides the CID PRS Voice Station Part The voice station part is configured...

Page 17: ...transmission The GPLIMT can also be self operated as a Managed Switch regardless of the WIM installation Board Name Abbreviations WIM WAN Interface Module LIM LAN Interface Module PLIM PoE LAN Interfa...

Page 18: ...2 3ab 1000 BASE TX IEEE 802 3 10 BASE TX IEEE 802 3u 100 BASE TX Connector Type RJ 45 SFP Small Form factor Pluggable Connector GPLIMT Interface Physical Connection IEEE 802 3 10 BASE TX IEEE 802 3u 1...

Page 19: ...IP server Physical Connection 100 BASE T Ethernet Signal Processing SIP Access Protocol User Agent UA to UA Interface between the call server and system manager Physical Connection 100 BASE T Ethernet...

Page 20: ...Standard SIP phones Wireless LAN phones The interface interworking standards between the VoIP elements based on the signal processing are as follows Proprietary TCP IPC SIP UA to UA UA to Server Figur...

Page 21: ...ramming can be only made in a station Operator Level Programming A technician can only program the programs specified in the Program 802 Range Specification of the Operator Program Programming can be...

Page 22: ...CHAPTER 1 Error Use the Home tab to apply 1 1 to the text that you want to appear here 1 10 SAMSUNG Electronics Co Ltd This page is intentionally left blank...

Page 23: ...eatures needed for a communication system The cabinet of the OfficeServ 7200 complies with the industry standards 19 inches and is assembled with firm and stable metal welding The OfficeServ 7200 hard...

Page 24: ...an anti static wrist strap for preventing static electricity can be connected when working on the system The OfficeServ 7200 hardware is designed to prevent electronic devices from being damaged due...

Page 25: ...controls the line boards and sends receives information to from the MP20 In addition line boards power and cooling fans are in the OfficeServ 7200 cabinets Figure 2 1 Cabinet Configuration of the Offi...

Page 26: ...t for PoE Power Switch Turn on off the OfficeServ 7200 power Power Connection Connector between Basic Cabinet and Extension Cabinet The connector to supply the supplied power to the external cabinet P...

Page 27: ...LCP TEPRIa and WIM Slot 3 All boards except for MP20 MP20S LCP and WIM Slot 4 5 All boards except for MP20 MP20S LCP TEPRIa and WIM The WIM can be mounted only on slot 1 of the basic and expansion ca...

Page 28: ...ed to the layer2 QoS management such as 802 1p Packet Preference 802 1q VLAN IGMP Snooping in addition to the layer 2 switch function If mounting LIM or PLIM to the slot 2 in the status that WIM is mo...

Page 29: ...Voice Trunk Line MP20 TEPRIa 8TRK 8TRK2 16TRK 4HTRK only China 4BRI except USA MP20S TEPRIa 8TRK 8TRK2 16TRK 4HTRK only China UNI Option Board 2BRM and 4TRM Voice Subscriber Line MP20 8SLI2 8DLI 8COMB...

Page 30: ...nchronization of the digital subscribers Option Board There are RCM2 MIS CRM IRM and Modem as option boards mounted in the MP20 The functions of these option boards are as follows R2 CID Module 2 RCM2...

Page 31: ...e and uses a modem chip for Central Office which can perform Pulse Code Modulation PCM highway interface In addition the MODEM supports V 90 protocol OfficeServ 7200 controls the MODEM via serial comm...

Page 32: ...connected On Green Booting Blink Green The Program is operating properly Blink Red Fan module failed Blink orange Reset button is pushed ON orange Flash Memory Data base clear LAN LED This LED indica...

Page 33: ...synchronous Receiver and Transmitter UART test External Internal Music On Hold MOH and Loud common bell functions Time setting and display function Phase Locked Loop APLL function for the synchronizat...

Page 34: ...BGA BALL GRID ARRAY SDRAM Memory for programs and data Capacity 128 MB Width of Data Bus 32 bit NAND Flash Capacity 128 MB Width of Data Bus 16 bit Flash ROM For Booting Capacity 512 KB Width of Data...

Page 35: ...Port to insert an MMC card which is a storage media RUN LED Status of Main CPU operation Off No power On Green On Booting Blink Green Normal Operation of Program Blink Red Fan module failed Blink ora...

Page 36: ...shown in the figure below Figure 2 5 Front View of the LCP The components on the front panel of the LCP have the functions below Table 2 9 Ports and LEDs of the LCP Ports LEDs Functions LINK1 3 Ports...

Page 37: ...output port by monitoring line signals Crystal less wander and jitter attenuation compensation to TR62411 Attenuates compensates jitter as recommended in ITU T I 431 and G703 Provides the selectable...

Page 38: ...rd is incorrect Off The frame synchronization with the opposite switchboard is correct LOS1 LED Indicates whether the opposite switchboard has a Loss of Signal LOS On The opposite switchboard signal i...

Page 39: ...riber line board Main Functions The main functions of UNI are as follows 3 pair of connector to mount an option module Option Module control logic 54 V power Control function Specifications Use of 4TR...

Page 40: ...n the position of MD1 MD2 and MD3 MD1 LED MD2 LED MD3 LED Module mounting status at the each MD position and subscriber status Off No module mounted On Red 4DLM mounted On Green 4TRM or 2BRM mounted O...

Page 41: ...rd sends voice through the trunk lines and transmits voice data of 64 Kbps to one channel Major Functions The 8TRK performs the functions below Detects ring connection Detects on off hook Sends dial p...

Page 42: ...used Blink The ring is being connected 2 3 2 4 8TRK2 The 8TRK2 provides 8 ports of analog trunk line and can support the PRS CID paths within a single board It provides the voice though the trunk line...

Page 43: ...and can support the PRS CID paths within a single board It also provides the voice though the trunk line each channel supports 64 Kbps voice data transmission Major Functions The 16TRK performs the fu...

Page 44: ...es 4 ports of analog trunk line and can support the DID E M and R D paths within a single board It provides the voice though the trunk line each channel supports 64 Kbps voice data transmission Major...

Page 45: ...ble 2 16 Ports and LEDs of the 4HTRK Ports LEDs Functions P1 4 Trunk Line Port P1 4 RD LED R D Port Operation Status Off Not being used On The trunk line is being used Blink The RD mode is being confi...

Page 46: ...Processes the T S0 mode signals by programming Uses 4 port T mode or selectively uses 4 port S0 Resistor Terminations for S0 line 100 Endures the ITU recommended level of surge Protects the output por...

Page 47: ...n International Telegraphy and Telephony CCITT I 430 Frame conversion between S T interface and ISDN Oriented Modular IOM Receive timing recovery according to a specific operation mode D channel acces...

Page 48: ...e two 2 ports 2 3 2 9 4TRM The 4 Port Trunk Module 4TRM is mounted on UNI and provides four 4 analog trunk ports A 4TRM provides both of the PRS and CID paths Key Functions The 4TRM provides the follo...

Page 49: ...onnection part within the 4TRM It is connected to an external line through the RJ 45 connector on the line connection part located at the left side of the system Figure 2 16 4TRM Table 2 19 Ports of t...

Page 50: ...mmunication Major Functions The major functions of the 8SLI2 are as follows Generates a ring signal of 20 25 Hz Detects DTMF dial pulse Detects on off hook Generates various audible tones Specificatio...

Page 51: ...hannel provided Interworking Number is limited on the internal Digital Phone Front View of the 8DLI The front view of the 8DLI is shown in the figure below Figure 2 18 Front View of the 8DLI The compo...

Page 52: ...erates the ring of 20 25 Hz Detects the DTMF dial pulse Detects on off hook Generates a tone Specifications The specifications of the 8COMBO2 are as follows 8 analog station ports 8 digital station po...

Page 53: ...in function of 16SLI2 16MWSLI is as follows Creating 20 25 Hz Ring Sensing Dial Tone Multi Frequency DTMF Dial Purse Sensing On Off Hook Creating Tone Power Fail Transfer PFT Message Waiting Function...

Page 54: ...Specification The specification of 16DLI2 is as follows Providing 16 extension ports Providing 1B D One voice channel and one signal channel Interworking Number is limited on the internal Digital Pho...

Page 55: ...ommunication function Specification The specification of the 4DLM is as follows 4DLM Provides four 4 station ports and 1B D a voice channel and a signal channel Board View The 4DLM is a daughter board...

Page 56: ...key functions of the 4SL2 are as follows 20 Hz ring generation Dial Tone Multi Frequency DTMF Dial pulse detection On Off hook detection Tone generation Specification The specification of the 4SL2 is...

Page 57: ...re as follows 20 Hz ring generation Dial Tone Multi Frequency DTMF Dial pulse detection On Off hook detection Tone generation Specification The specification of the 4SLM is as follows 4SLM Four 4 stat...

Page 58: ...with the xDSL or cable modem WAN1 Provides the Ethernet port of 10 BASE T for backup WAN2 Offers the DeMilitarized Zone DMZ service Provides the Ethernet port of 10 100 BASE T for the LAN interface P...

Page 59: ...ial dedicated line that interworks with the V 35 RUN LED This LED indicates the operation status of the WIM Off The WIM board is in an abnormal status or the power is not being supplied On The WIM boa...

Page 60: ...10 100 BASE T or full half duplex automatically Offers the VLAN for supporting QoS Functions as a switching hub Specifications The LIM provides 16 ports of 10 100 BASE T Front View of LIM The front vi...

Page 61: ...anel it is available to use all 16 ports LAN Main Function The main function of the LIM is as follows 10 100 BASE T Full Half duplex automatic sensing function The VLAN function for the QoS support Th...

Page 62: ...e through using the shunt pin The detail is described in OfficeServ 7200 Installation Manual 2 3 4 4 PLIM2 The PLIM2 transmits the data through the intranet and provides a 10 100 BASE T interface It p...

Page 63: ...he link is operating LED is turned on into green color Blink When each port is active the LED is blinking Second LED Indicates whether the P1 4 P9 12 are operating in 10 100 BASE T mode Off In operati...

Page 64: ...ajor Functions The major functions of the GPLIMT are as follows L2 Ethernet Switching 10 100 BASE Full Half duplex auto sensing VLAN Networking 802 1q Packet Priority Control 802 1p Flow Control 802 3...

Page 65: ...perating in 10 100 BASE T mode Off In operation as 10 BASE T On In operation as 100 BASE TX Right LED of P1 6 First LED Indicates if the P7 12 s link is operating On When the link is operating LED is...

Page 66: ...Ethernet Switch 802 3 compatible 10 100 1000 BASE TX port Packet Priority Control 802 1p VLAN Networking 802 1q Spanning Tree Protocol RSTP PVST Diffserv Flow Control 802 3x Multi casting IGMPv1 v2 DV...

Page 67: ...Blinking The RAM programming is running LNK LED Turns on if the DBL port link is connected SPD LED Indicates whether the DBL port is operating in 10 100BASE T Ethernet mode Off In operation as 10 BAS...

Page 68: ...Booting Blink The RAM program is operating LAN Tx LED This LED indicates the status of the Ethernet data transmission Off Data does not exist On or blink Data is being transmitted LAN Rx LED This LED...

Page 69: ...er slot If any board is mounted on the other slot the board will not work Major Functions The major functions of the OAS are as follows Voice decompression Codec G 729 G 723 and G 711 Fax Relay Functi...

Page 70: ...ception status of the link and Ethernet data Off Data does not exist or the link is not connected On or blink Data is being received SVC1 LED This LED indicates if the MGI service is being offered Thi...

Page 71: ...s a phone call to the system to attend the conference Supports Pre defined conference which the chairperson makes phone calls for a specific group at once to invite members to the conference Supports...

Page 72: ...is operating SVC LED This LED indicates if the CNF24 service is being offered This LED turns on when the CNF24 software task can be serviced LAN LED This LED indicates the status of the Ethernet link...

Page 73: ...re mounted SVMi 20E provides all necessary voice mailbox function This SVMi 20E is the product that is easy to use and install The SVMi 20E is not available for MP20S Main Function Main Function and F...

Page 74: ...ected the relevant LAN connector SIO Used to connect to PC RST If pushing this button SVMi 20E system starts and the call in progress is disconnected VM1 LED When one or more ports are hooked on off i...

Page 75: ...ransmission and connected to the ports of the 8DLI 16DLI2 8COMBO2 mounted on the Universal slot of the OfficeServ 7200 The digital phones can be used by connecting with devices such as Add On Module A...

Page 76: ...es Desk or wall mounted 7 Button 2 Line LCD Keyset DS 5007S 48 character display 2 24 LCD with 3 associated soft keys and scroll key 7 programmable keys 5 fixed function keys Built in speakerphone Key...

Page 77: ...ringer volumes Desk or wall mounted 12 Button Large LCD Keyset DS 5012L Large LCD with 12 keys for feature selection Supports data transfer handset calls and full duplex speakerphone USB interface Nav...

Page 78: ...or feature selection Supports data and voice transfer using Internet Protocol Navigation keys for easy use of Keyset functions 5 fixed function keys Keyset Status Indicator 8 selectable ring tones Vol...

Page 79: ...rphone Keyset Status Indicator 8 selectable ring tones Volume Up Down keys for digital control of speaker handset and ringer volumes Desk or wall mounted The 5100 Series IP Keysets are as follows 12 B...

Page 80: ...speakerphone Keyset Status Indicator 8 selectable ring tones Volume Up Down keys for digital control of speaker handset and ringer volumes Desk or wall mounted 21 Button 2 Line LCD IP Keyset ITP 5121D...

Page 81: ...Status Indicator 8 selectable ring tones Volume Up Down keys for digital control of speaker handset and ringer volumes Desk or wall mounted 5 Button 2 Line LCD Keyset SMT i3100 128 character display 8...

Page 82: ...that provides a Digital Line Interface DLI port for connection of a digital station device such as a keyset or 64 button add on modules KDB Subscriber Line Interface KDB S If your keyset is connected...

Page 83: ...use with the door phone unit The unit is commonly used to request entry through locked doors interior or exterior or as a room monitoring box It provides contact control to be used with a customer pro...

Page 84: ...AN RF interface with the wireless frequency band of 5 GHz Figure 2 36 SMT R2000 The wire Ethernet interface is connected with the LAN based on 10 100 BASE T and transmits receives data e g Internet ac...

Page 85: ...istance The output resistance of FM radios CD players or cassette recorders are 8 to 16 2 6 2 External Units The OfficeServ 7200 is connected with external units such as amplifiers or speakers for con...

Page 86: ...CHAPTER 2 Error Use the Home tab to apply 1 1 to the text that you want to appear here 2 64 SAMSUNG Electronics Co Ltd This page is intentionally left blank...

Page 87: ...ending on the user s needs Table 3 1 below shows the maximum line capacity of the OfficeServ 7200 Below are the system configuration and the capacities of the system Table 3 1 System Configuration Cat...

Page 88: ...ixed at 14 The minimum of each channels are 6 and can be expanded to 8 If the user wants to use 8 MFR channels the Mobex channels will be 6 channels and vice versa Table 3 3 System VM MGI MPS Capacity...

Page 89: ...TRK 32 24 SPnet TRK 64 32 TRK Total 64 60 Total STN TRK 192 124 Etc Virtual Cabinet 6 5 MOBEX standard 120 60 MOBEX executive 64 60 BHCA 0 45 erl 90 sec 3 200 2100 Condition In case of the unconditio...

Page 90: ...4 8 RCM2 CID 4 14 4 14 RCM2 R2 CID 4 4 6 4 4 6 IRM MFR R2 CID 4 4 16 8 16 IRM provides additional 4 ch CRM MFR 4 4 12 20 CRM provides additional 4 DTMF Receivers because Engine has 4MFR CRM R2 4 4 14...

Page 91: ...6 14 CRM CID 4 12 14 16 14 CRM R2 CID 4 12 8 6 16 8 6 In case of MP20 the maximum line capacity is basic cabinet expansion cabinet column but in case of MP20S the maximum line capacity is basic cabine...

Page 92: ...ty Control Board System Configuration Analog phones Digital Phones ITP MP20 MP20S Basic cabinet 80 80 24 DS 5012L 8 board 16 PoE Internal PSU 120 use without PoE MP20 only Basic cabinet expansion cabi...

Page 93: ...e set loop Figure 3 1 Trunk Line Loop Start Signaling T1 Trunk Line The electrical characteristics of the T1 trunk line comply with the ITU G 703 and G 704 standards Table 3 9 Electrical Characteristi...

Page 94: ...al and pulse 244 ns Jitter of the I O terminal Refer to the G 823 Transmission media A pair of twisted lines Load resistance 120 Indicated pulse nominal peak voltage 3 00 V Blank non pulse peak voltag...

Page 95: ...0 300 V The electrical characteristics of the Digital Line Interface DLI are shown in the table below Table 3 13 Electrical Characteristics of the DLI Line Category Specification Transmission speed 38...

Page 96: ...Characteristic resistance 100 Indicated pulse nominal peak voltage 10 V Input threshold 0 3 V 3 2 1 3 Signaling Type of the LAN The electrical characteristics of the 10 BASE T which complies with the...

Page 97: ...d Crossover UTP cable The Straight through UTP cable is used to connect the OfficeServ 7200 s LIM PLIM module with other modules MP20 MGI16 WIM The Crossover UTP cable is used to connect between the L...

Page 98: ...istics of 1000 BASE Sx LX Fiber Optic Fiber Type Mode Band Short Wave Long Wave MHz Km Transmission Distance m 1000BASE SX 1000BASE LX 62 5uM MMF 160 500 220 550 200 500 275 550 50uM MMF 400 400 500 5...

Page 99: ...f analog phones 3 2 2 Transmission Characteristics Attenuation Attenuation between subscribers Less than 6 dB Attenuation between the subscriber and local trunk line Less than 0 5 dB Characteristic re...

Page 100: ...rd The rating is as follows RATING AC 220 240 V 6 A 50 60 Hz or DC48 V 3 A RATING AC 100 120 V 6 A 50 60 Hz or DC48 V 3 A for U S A Table 3 21 Power Specifications Power Supply Unit PSU Specification...

Page 101: ...IM Because the internal power capacity is not enough 48 V power source is supplied to the external equipment by connecting the supplementary power source Figure 3 2 External Rectifier Installing an Ex...

Page 102: ...0 ms Station ring 400 200 400 3000 ms Door ring 400 200 400 200 400 2000 ms Alarm ring 400 200 400 200 400 200 400 1000 ms Ring ON OFF Cycle The ON OFF cycle can be adjusted by changing the values of...

Page 103: ...0 500 ms Do Not Disturb tone 250 250 ms Ring Back tone 1000 2000 ms Call Park tone Continuous Confirmation Caution Barge In tone 50 50 ms Call Back Hold tone 500 3500 ms Ring Back tone 1000 2000 ms Er...

Page 104: ...24E DS 2021E DS 3020S IP phone ITP 5121D 5114D 5107S ITP 5112L SMT i3100 Wireless LAN device WLAN SMT W5100 MS SMT R2000 Access Point device DSS DS 64B AOM DS 5064BAOM DS 4014AOM DS 4064AOM DS 24SE AO...

Page 105: ...of the two cabinets shown in the figure below Figure 3 3 Cabinet Configuration of the OfficeServ 7200 When the OfficeServ 7200 consists of one cabinet basic cabinet 440 W 123 8 H 410 D mm When the Off...

Page 106: ...1719 For connection with Gatekeeper TCP 1720 For connection setup 1024 4999 For maintaining TCP Connection SIP Gateway UDP 5060 For connection setup OSM interface TCP 5000 5200 OSM connection CTI inte...

Page 107: ...5199 Reserved for new service QoS Monitor 8500 QoS Monitor Server connection NMS NMS UDP 161 Well known port Can set 1024 65535 MGI OAS MGI 16 OAS RTP RTCP 10000 60000 For stream data Flexible assign...

Page 108: ...511 RTP RTCP RTP 1 TCP 8080 Web Admin 20001 File Server 3681 50000 55999 Outlook Sync Protocol 25 Mail Alarm SMTP 110 995 Pop3 Pop3 SSL 8624 Port Activity Monitor Program IP IVR UDP 5060 SIP Port ACD...

Page 109: ...5100 Live Push Audio 35102 Live Push Video 5000 6000 Internal Station 20000 20100 External Station 6000 7000 Internal Recording 20100 20120 External Recording MCS UDP Dynamic SIP System Default 5060 n...

Page 110: ...CHAPTER 3 Error Use the Home tab to apply 1 1 to the text that you want to appear here 3 24 SAMSUNG Electronics Co Ltd This page is intentionally left blank...

Page 111: ...d VoIP networking 4 1 1 Dynamic IP Address Allocation MGI16 Configuration The MGI16 mounted in the OfficeServ 7200 can be alternatively operated by automatically receiving the dynamically allocated IP...

Page 112: ...d public IP which enables the OfficeServ 7200 to provide services smoothly Each IP address is translated automatically This function operates only between the call server and data server of the Office...

Page 113: ...re identified by the SIP address in the e mail format This function saves and manages the current user s IP address after giving a priority to the IP address Then this function provides the user infor...

Page 114: ...management package 4 2 6 Forward Busy The call server always monitors the SIP telephone status through the SIP server If the Forward Busy function is set the incoming call is forwarded to the specifi...

Page 115: ...ding loop in the switch 802 1p Packet Priority The switch extracts the priority field from the Ethernet frame configured according to the 802 1p specification standard and discriminatively processes t...

Page 116: ...fficeServ 7200 configures a fixed routing table between each network interface to process the static routing In this case the routing table cannot be dynamically changed by the routing protocol and sp...

Page 117: ...icast groups to nearby routers The multicasting allows a host computer to send the contents to pre specified other IP terminals or Internet computers The multicasting is used for modifying the address...

Page 118: ...e IP address that is not applied by the NAT PT conversion Redirect When the DNS server IP in the data server management sector is changed each IP terminal uses the pre DNS IP and this function changes...

Page 119: ...otify the system administrator and protect the packets Virtual Private Network VPN VPN function The system provides the private network function by using the Internet that is an open network The Offic...

Page 120: ...o the NAT PT table in the data server When using the data server of the OfficeServ 7200 the SIP equipment can operate regardless of the packet blocking cased by the firewall or the MAT PT conversion S...

Page 121: ...file to a media card Software Package Upload The admin user can explore the current package in media card and upgrade it User Account Management The admin user can add and delete User ID and can chan...

Page 122: ...ceServ NMS through SNMP Agent The OfficeServ NMS is a Network Management System NMS providing the OfficeServ system s operation and maintenance function Additionally the OfficeServ NMS has the followi...

Page 123: ...free software we are referring to freedom not price Our General Public Licenses are designed to make sure that you have the freedom to distribute copies of free software and charge for this service i...

Page 124: ...h a written offer valid for at least three years to give any third party for a charge no more than your cost of physically performing source distribution a complete machine readable copy of the corres...

Page 125: ...DITIONS How to Apply These Terms to Your New Programs If you develop a new program and you want it to be of the greatest possible use to the public the best way to achieve this is to make it free soft...

Page 126: ...library in non free programs enables a greater number of people to use a large body of free software For example permission to use the GNU C Library in non free programs enables many more people to u...

Page 127: ...debugging such modifications You must give prominent notice with each copy of the work that the Library is used in it and that the Library and its use are covered by this License You must supply a cop...

Page 128: ...Foundation 14 If you wish to incorporate parts of the Library into other free programs whose distribution conditions are incompatible with these write to the author to ask for permission For software...

Page 129: ...HT HOLDERS AND CONTRIBUTORS AS IS AND ANY EXPRESS OR IMPLIED WARRANTIES INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED IN NO...

Page 130: ...Annex A Error Use the Home tab to apply 9 1 to the text that you want to appear here A 8 SAMSUNG Electronics Co Ltd This page is intentionally left blank...

Page 131: ...cked Loop ASIC Application Specific Integrated Circuit AWG American Wire Gauge B BRI Basic Rate Interface BRM Basic Rate interface Module BoD Bandwidth on Demand C CAS Common Associated Signal CBQ Cla...

Page 132: ...e Multi Frequency E EMC Electro Magnetic Compliance EMI Electro Magnetic Interference F FXS Foreign eXchange Station FXO Foreign eXchange Office G GK GateKeeper GPLIMT Gigabit PoE LAN Interface Module...

Page 133: ...terface MIS Miscellaneous MMC Man Machine Communication MPD Metering Pulse Detection N NAT Network Address Translation O OAS OfficeServ Application Server OSPF Open Shortest Path First P PCM Pulse Cod...

Page 134: ...erface Module SMDR Station Message Detail Recording SME Small Medium Enterprise STP Signaling Transfer Point SMTP Simple Mail Transfer Protocol SWM Switch Module T TAPI Telephony Application Programmi...

Page 135: ...OfficeServ 7200 System Description SAMSUNG Electronics Co Ltd V W WAN Wide Area Network WIM WAN Interface Module WLAN Wireless Local Area Network...

Page 136: ...Error Use the Home tab to apply 8 1 to the text that you want to appear here VI SAMSUNG Electronics Co Ltd This page is intentionally left blank...

Page 137: ...mercial wastes for disposal EEE Y netmeli ine Uygundur This EEE is compliant with RoHS BATTERY SYMBOL INFORMATION Correct disposal of batteries in this product Applicable in the European Union and oth...

Reviews: