8.  Attach and close the front grille.

  

   Make sure the hooks on the rear side of grille fits properly into the 

grooves on panel (

) and then push the panel to close (

).  

9.  Check out that the panel is fixed to the indoor unit.

  

   Fix screws tightly between the panel and the surface of the ceiling. 

If the panel is installed incorrectly, air may leak. 

  

  Do not block any discharge vents in the panel.

7.  Close the electrical component box cover and tighten the screws.

Grille

Hook

For 4 way cassette

•   If the angle on the air flow blades has been changed by user due to opening the front grille for installation or 

maintenance, you must turn off the circuit breaker and turn it on again before using the air conditioner.  

Otherwise, angles of the each angle can be different or some of the blade may not close when the product is off.

NOTE

Panel Global 4way_IM_E 32728-1.indd   4

2010-11-04   오전 11:16:17

Summary of Contents for PC4NBSKA

Page 1: ... Air Conditioner installation manual imagine the possibilities Thank you for purchasing this Samsung product To receive more complete service please register your product at www samsung com register Panel Global 4way_IM_E 32728 1 indd 7 2010 11 04 오전 11 16 18 ...

Page 2: ...lle to open Handles are located on the left and right side of the Samsung logo on the grille You may have to open the air flow blades first in order to find the handles Detachthefrontgrille 1 Remove the safety clips first 2 Pull the green switch on the hinge part towards the sign and press and pull the hinge part to remove the grille There are two hinges on the grille and you must apply this step ...

Page 3: ...ng 2 hooks on the both sides of the indoor unit Hook Groove 5 Fix the bolt to the panel 1 Fix 4 bolts to the panel temporarily 2 Fix them tightly not to make a gap between the panel and the ceiling 6 Connect 3 cables between the indoor unit and the panel Make sure you check the number of pins on the two white terminal before connecting the cables Panel White 11 PIN White 10 PIN Blue Panel Global 4...

Page 4: ...o not block any discharge vents in the panel 7 Close the electrical component box cover and tighten the screws Grille Hook For 4 way cassette If the angle on the air flow blades has been changed by user due to opening the front grille for installation or maintenance you must turn off the circuit breaker and turn it on again before using the air conditioner Otherwise angles of the each angle can be...

Page 5: ...ENGLISH 5 Memo Panel Global 4way_IM_E 32728 1 indd 5 2010 11 04 오전 11 16 17 ...

Page 6: ...Panel Global 4way_IM_E 32728 1 indd 6 2010 11 04 오전 11 16 18 ...

Reviews: