4. Alignment and Troubleshooting
4.7.2.2. Ax-xxxx (Motor_Fan_Sensor error)
► Error Code
A1-1210
► Error message
Error: #A1-1210 Turn off then on
► Symptom
The fuser motor does not operate. / The fuser motor is operating but is recognized as stop status.
► Troubleshooting method
1) Turn the machine off then on. If the error persists, turn the machine off again.
2) Remove the rear and right cover.
3) Check if there are any obstacles or paper around the fuser unit.
4) Check if the connection between main board and fuser motor are correct.
5) If the connection is OK, replace the fuser motor.
6) If there is a driver test for this component, please try it first. If the problem persists, replace the main board.
Copyright© 1995-2017 SAMSUNG. All rights reserved.
4-30