39
13. Installation
13-2. Outdoor unit
Outdoor unit installation
The outdoor unit must be installed on a rigid and stable base to avoid any increase in the noise level and vibration, particularly if the outdoor unit is to be installed
in a location exposed to strong winds or at a height, the unit must be fixed to an appropriate support(wall or ground).
Fix the outdoor unit with anchor bolts.
NOTE
• The anchor bolt must be 0.79 inch or higher from the base surface.
Anchor bolt hole
(Unit : inch)
11
.2
2
12
.4
8
13
.5
0
24.09
31.10
(Unit : inch)
Anchor bolt hole
12
.2
13
.4
14
.3
26.0
34.6
A Type : AC009KXADCH
B Type : AC018JXADCH
(Unit : inch)
Anchor bolt hole
13
.0
14
.2
15
.1
24.4
37.0
C Type : AC030/36MXSCCC
उ
CAUTION
• Make a drain outlet around the base for outdoor unit drainage.
• If the outdoor unit is installed on the roof, you have to check the ceiling strength and waterproof the unit.