• In order to avoid the creation of a flammable gas-air mixture
if a leak in the refrigerating circuit occurs, the size of the room
in which the appliance may be sited depends on the amount of
refrigerant used.
• Never start up an appliance showing any signs of damage. If
in doubt, consult your dealer. The room must be 1 m³ in size
for every 8 g of R-600a refrigerant inside the appliance. The
amount of refrigerant in your particular appliance is shown on the
identification plate inside the appliance.
• Refrigerant squirting out of the pipes could ignite or cause an eye
injury. When refrigerant leaks from the pipe, avoid any naked
flames and move anything flammable away from the product and
ventilate the room immediately.
- Failing to do so may result in fire or explosion.
• It is hazardous for anyone other than an Authorized Service
Person to service this appliance. In Queensland – the authorized
Service Person MUST hold a Gas Work Authorization or Licence for
hydrocarbon refrigerants, to carry out Servicing or repairs which
involve the removal of covers. (For Australia only)