82
TROUBLESHOOTING
4-2-2. If FAN does not operate
- The refrigerator of this model has BLDC FAN motor. BLDC motor is driven by DC 7~12V.
- On the normal condition of COMP ON, it operates together with F-FAN motor.
If door is opened and closed once at a high ambient temperature, it will be operated after 1 minute delay.
Therefore, you are advised not to taken it for an error.
-. If there is a trouble, you should select the self-diagnostic function to check the trouble before power off.
Start
Is COMPRESSOR ON ?
Door & MICOM State
Door
F FAN pulse voltage
CN76 “7”(Brown)
The voltage measured around 2~3V
with multi-meter though the voltage is
very weak because of pulse signal
☞
Display for checking the self-diagnostic function
PCB Typical Ground
J23 JUMMPER
F MICOM
(#29)
Close
Open
0V(Low)
5V(High)
0V(Low)
5V(High)
R MICOM(#28)
Right and Left
Execute manual
operation
FAN work normally
Repair the connection
of Door switch
Replace MAIN PCB Ground
1) F-FAN
PCB Typical Ground
J23 JUMMPER
Power ON with 7 minutes
delay
after power OFF.
For preventing the over load of
compressor)
• Expected causes
①
Check that if FAN-MOTOR has failure itself.
②
Check that if wiring connection has bad contact.
③
Check the input of the fan motor rotation pulse
when motor fan operates.
CN76-7(F),8(R),9(C)will generate the pulse signal when motor rotates.
These signals will be inputted into MICOM.
Unless signals are not inputted during motor operating, will be ON 10
seconds after fan Off. But if signals are not still entered, the above
operation will restart four times more.
If signals are not entered continuously, the motor will be restarted after 10
Minutes. This function is effective when the normal operation of motor
would be restrained by foreign matters such as ice.
The voltage between PCB typical Ground J23 JUMMPER and
F FAN ; CN76 ”3”(Yellow) shall be less than DC 7~12V.
R FAN ; CN76 ”4”(Orange) shall be less than DC 7~12V.
C FAN ; CN76 ”5”(Sky-blue) shall be less than DC 7~12V.
- Recheck if resistance values are different after measuring.
Is the voltage between MAIN
PCB Ground J23 JUMMPER and CN 76
”3” (Yellow) around DC7~12V?
Is the voltage between MAIN
PCB Ground J23 JUMMPER and CN
76”5”(Sky -blue) around DC7~12V?
Is the voltage between MAIN
PCB Ground J23 JUMMPER and CN
76”4” (Orange) around DC7~12V?
Is the external temperature
above 66.2
℉
(19
℃
)?
Recheck after 7 minutes
(Time could be delayed
depending on the
temperatures. If the
temperature is lower, It
may not operate : about
59
℉
(below 15
℃
)
Is the voltage between MAIN
PCB Ground J23 JUMPER and CN
76-"12"(Purple) around 0V?
Is the voltage between MAIN
PCB Ground J23 JUMMPER and CN76-
"11" (White) around 4.5~5V?
Does DC7~12V alternate with
below DC 2V between MAIN PCB Ground
J23 JUMMPER and CN76 “3”(Yellow)
Does DC7~12V alternate with below
DC 2V between MAIN PCB Ground J23
JUMMPER and CN76 ”4”(Orange)
Does DC7~12V alternate with
below DC 2V between MAIN PCB Ground J23
JUMMPER and CN76 ”5”(Sky-blue)
In initial power to appliance, the compressor
and fans of fresh food/ freezer, compressor
fan operate. If freezer temperature is sensed
of 41
℉
by momentary power failure, fans will
operate after 7 minutes.
Reference
2) R-FAN
3) C-FAN
R FAN ERROR
(Option)
F FAN ERROR
C FAN ERROR