59
4-1-3. Self-diagnostic function
1-1) Micom operates self-diagnostic function to check the temperature sensor condition within 1 second
when the refrigerator turned On initially.
1-2) If bad sensor is detected by the self-diagnostic function, the applicable display LED will blink for 0.5
sec.
At this moment, there is no beep sound.(Refer to self-diagnostic CHECK LIST)
1-3) Self-diagnostic button is recognized only when the error is displayed by the bad sensor. Display does
not operate normally but temperature control will be controlled by the emergency operation.
1-4) When the error is detected by self-diagnosis, the error can be canceled automatically if all troubled
sensors are corrected or Self-diagnostic function key (Energy Saver Key + Lighting Key ) are pressed
simultaneously for 8 seconds.
(Return to normal display mode)
2-1) If Energy Saver Key + Lighting Key are pressed simultaneously for 6 seconds during normal operation,
the temperature setting display will operate for 2 seconds (ON/OFF 0.5sec each).
If Energy Saver Key + Lighting Key are pressed simultaneously for 8 seconds (including above 2
seconds), self-diagnostic function will be selected.
2-2) At this moment, self-diagnostic function will be returned with buzzer sound 'ding-dong'.
If there is an error, display of error will be operated for 30 seconds and then return to normal condition
whether problem is corrected or not.
(Refer to self-diagnosis CHECK LIST)
2-3) Input by button is not accepted during self-diagnostic function.
1) Self-diagnostic function in the Initial power ON
2) Self-diagnostic function during normal operation
TROUBLESHOOTING
①
①
①
①
①
①
①
①
①
If Energy Saver Key + Lighting Key are pressed simultaneously
for 8 seconds, the error mode by self-diagnosis will be canceled.
①
If Energy Saver Key + Lighting Key are pressed simultaneously
for 8 seconds, the error mode by self-diagnosis will be canceled.
AW3 SM-EN 2011.3.31 2:55 PM 페이지59 in
Summary of Contents for RF4287HARS
Page 17: ...18 PRODUCT SPECIFICATIONS 2 5 Dimensions of Refrigerator Inches AW3SM EN2011 3 312 52PM 18 in...
Page 86: ...87 TROUBLESHOOTING IPM FREEWHEELING DIODE VOLTAGE VALUE AW3SM EN2011 3 312 56PM 87 in...
Page 96: ...97 TROUBLESHOOTING SPM Internal DIODE Voltage AW3SM EN2011 3 312 56PM 97 in...
Page 98: ...99 TROUBLESHOOTING INVERTER PCB Circuit Diagram AW3SM EN2011 3 312 56PM 99 in...
Page 124: ...125 7 1 Model RFG295AA BETTER 7 WIRING DIAGRAM BLU BLU AW3SM EN2011 3 312 57PM 125 in...
Page 125: ...126 7 2 Model RF4287AA BEST 7 WIRING DIAGRAM AW3SM EN2011 3 312 57PM 126 in...
Page 126: ...127 7 3 Model RFG299AA 7 LCD 7 WIRING DIAGRAM BLU BLU AW3SM EN2011 3 312 57PM 127 in...
Page 127: ...128 7 4 Model RFG294AA SEARS 7 WIRING DIAGRAM AW3SM EN2011 3 312 57PM 128 in...
Page 129: ...130 8 SCHEMATIC DIAGRAM 8 1 2 INVERTER BLOCK RF4287 AW3SM EN2011 3 312 58PM 130 in...
Page 130: ...131 8 2 CIRCUIT DIAGRAM SCHEMATIC DIAGRAM 8 2 1 MAIN AW3SM EN2011 3 312 58PM 131 in...
Page 131: ...132 SCHEMATIC DIAGRAM 8 2 2 INVERTER AW3SM EN2011 3 312 58PM 132 in...