                      Heat Release I/M Test Mode

                                                                        

Press and hold the ICE TEST S/W for at least 1.5sec, the 
harvest function will start.  If the ice maker Thermistor is be-
low 0 degrees the Ice maker heater turns on for about 2 min-
utes. If the temperature exceeds 0 degrees, Ice maker 
heater turns on for 30 seconds. After the Ice maker heater 
turns on for 30 seconds, the heater turns off and then Ice 
maker harvest motor turns on.  The motor will rotate in right 
direction for about 3 minutes, after this, water supply valve is 
turned on, then the valve is turned off, the test mode is com-
pleted. If the above operation is not carried out within 6 min-
utes, it will go into a fault mode.  

           Heat Release Ice Production Explanation                           

38 minutes after the water fill is complete, the control 
board will check the temperature of the eject Thermistor,  
on the Ice Maker Head, if the Thermistor reads a tem-
perature lower than 18.5 degrees for more than 5 sec-
onds, then the ice production process is completed. The 
Ice maker will harvest if the ice bucket is not sensed as 
full.  If a Fault Mode is detected with the Ice Maker op-
eration, the Ice Maker stops working for 3 hours. Which 
means, the Ice Maker checks the operation every 3 
hours until it works properly.

 

 

                                                 FREEZER TEMPERATURE CONTROL BY THE ICE MAKER    

Interior Temperature of the freezer will be set to -14 degrees Fahrenheit until the ice bucket is full. When the ice 
bucket is full, the freezer will maintain original set temperature. Also, whenever the ice is used, the freezer will 
again set to -14 degrees Fahrenheit. Selecting "Ice Off” will allow the freezer to be controlled by the set tem-
perature. If water is not hooked up, the freezer will always be at –14 unless “Ice Off” is selected.

 

Heat Release Ice Makers 

 

FLEX TRAY Ice Makers 

When the initial power is applied, the ice tray will stand by for 2 hours.     
After the 2-hour standby time, the Ice Maker Sensor will check  
the temperature, when it is lower than 1.5

  for more than 5 minutes, 

it will do a harvest, with or without ice in the tray,  then fill with water.  
58 minutes after water is supplied to the Ice Tray, the Ice Maker  
Sensor temperature will be checked. When the Ice Maker Sensor  
maintains lower than  1.5

  for 5 minutes, it completes the harvest 

(if the ice bin is not sensed as full).   
Thermistor senses temperature to determine water fill on newer units  

Filling the tray

 

After the water fill is completed, the ice maker sensor will evaluate the  
water volume one and a half minutes later. When it detects no or low  
water level, it will add more water. First supply time will be 1.5 sec,  
next one will be 1 sec  and the last will be 2 sec.

 

Shattered Ice – Flex Tray 

When all ice shatters, it's because of a bad 

tray or ice cube temp that is too cold (lower 

than -5 degrees). In some areas, there are 

water issues that can also cause shattered 

cubes. The temp in the freezer should not 

have any effect on this issue, as long as it’s 

below 1.5 degrees F, as a properly installed 

sensor will not read the freezer temp, only the 

water/ice temp. 

Check the Ice tray for defects in the plastic. 

Ice that is too cold will shatter during          

harvest. This can be from the (1) sensor not 

reading the correct temp (2) or the sensor not 

mounted correctly (3). By programming the 

icemaker offset value to a lower number (4), 

the board not understanding the reading. 

To check the sensor, you must check the tray 

temp (not air temp) and compare it to the sen-

sor reading. The sensor should read 3.7 volts 

at the main board connector when the cube 

temperature is 1 degree. After the fill, the sen-

sor will read water temp 1.5 to 2.2 volts. 

To clear offsets, put unit into Diagnostics 

mode. 

Please note, some shattering is normal for 

a flex tray icemaker. 

Guide – Bin Full

 

Ice Maker Thermistor

 

Ice Maker Test Button

 

First Defrost Cycle, Both 

Defrost Cycle Fridge only

 

Defrost Cycle Fridge & Freezer

 

13 hrs,  Pause Time 10 minutes

 

 6~11 hrs (varies according to 

conditions)

 

12~22 hrs (varies according to conditions)

 

Defrost Cycle Timing

 

FLEX TRAY Ice Makers 

Summary of Contents for RFG298AA**/XAA

Page 1: ...Saver Fridge simul taneously No sound when both buttons are pressed at the same time til it beeps and goes blank 8 12 seconds Publication tsRFG298AA Revision Date 03 30 2011 Component Value Chart Press Freezer button a second time to Force Mid Speed Run 3600RPM 2450RPM 2200RPM NOTICE Parts Change The interior lighting changed from incandescent lighting to LED lighting The new parts are NOT interch...

Page 2: ...ivity for 5 cycles 10 seconds off 3 seconds on the fan drive circuit is disabled for 10 minutes TO TEST THE FAN CIRCUIT VOLTAGE Power off and back on to check the DC voltage to the motor wait from 10 to 60 seconds for the fan voltage to kick in and then check fan voltage the average reading is 9 VDC If you get 3 seconds of voltage every 10 seconds for the 5 fan power up cycles then the Main PCB is...

Page 3: ... Sensor will check the temperature when it is lower than 1 5 for more than 5 minutes it will do a harvest with or without ice in the tray then fill with water 58 minutes after water is supplied to the Ice Tray the Ice Maker Sensor temperature will be checked When the Ice Maker Sensor maintains lower than 1 5 for 5 minutes it completes the harvest if the ice bin is not sensed as full Thermistor sen...

Page 4: ...e error is displayed after three failed attempts Replace I M WATER HEATER ERROR Error is displayed w hen the w ater reservoir tank heater is open or shorted Disconnect heater connector from PCB check resistance EXT SENSOR Ambient Temp Sensor Error open or short circuit connector failure Cause is also a temperature reading 122 or 58 F The voltage at MAIN PCB Sensor betw een 4 5V 1 0V F SENSOR Freez...

Page 5: ...30 2011 5 SERVICE BULLETIN PRODUCT Refrigerator BULLETIN NUMBER ASC20100714001 DATE 07 14 2010 Please review before ordering any parts CN78 1 3 Fz LED Blk Gry 4 7 FF LED Red Gry CN71 All 120vac 5 N Gry 9 Def Htr Common Org ...

Page 6: ...2 Red Blk 5vdc CN75 To Comp Inverter Board 1 CN76 1 Blk Gry 13vdc 2 CN76 1 Brn Gry 5vdc 4 3 Compressor control Org Red 2 2 8vdc CN79 2 7 Fill tube heater freezer Blu Wht 13vdc 3 7 Water Tank Htr Pnk Wht 13vdc CN30 Sensors Switches 1 5 Freezer Dr Sw Blk Gry 5vdc 1 5 Freezer Dr Sw Blk Gry 5vdc 2 CN50 7 R Door Sw Prp Gry 5vdc 3 CN76 1 F Sensor Red Gry 3 5 4 2vdc 4 CN76 1 F Def Sensor Org Gry 2 3 4 2v...

Page 7: ... tsRFG298AA RevC 03 30 2011 7 Late Production change ...

Page 8: ...nd check resistance to the windings Aproxametly10 ohms If not correct inspect wire harness if OK replace compressor 5 Disconnect CN02 SMPS PCB check resistance to Overload if open replace overload CN04 Compressor Control 2 CN40 4 5vdc Brn Gry 4 Comp Signal Org CN03 Compressor Windings 1 Compressor Blue 3 Compressor Prp 5 Compressor Wht CN02 Overload A C Line 1 OLP Brn 3 OLP S Blu 3 L Blk 1 N Red C...