#  tsRFG298AA  RevC 03/30/2011

                                                                                                                                                       4 

 

Error Items

LED

TROUBLE

TESTING

I/M-SENSOR (R on Tw in 
I/M units) 

Ice Maker Sensor Error- open or short-circuit, connector failure. Cause is 
also a temperature reading > 122°or < -58 ° F

The voltage at MAIN PCB Sensor 
betw een 4.5V~1.0V

R-SENSOR 

Refrigerator Room Sensor Error- open or short-circuit, connector failure. 
Cause is also a temperature reading > 122°or < -58 ° F.

The voltage at MAIN PCB  Sensor 
betw een 4.5V~1.0V

DEFROST SENSOR OF R 
ROOM 

Ref. Defrost Sensor Error- open or short-circuit, connector failure. Cause is 
also a temperature reading > 122°or < -58 ° F

The voltage at MAIN PCB Sensor 
betw een 4.5V~1.0V

R-FAN ERROR 

This error indicates the Refrigerator Evap Fan is not spinning at the correct 
RPM or the fan feedback line is open.

Fan voltage at MAIN PCB  shall be 
betw een 7V~12V

I/M FUNCTION ERROR(R 
on Tw in I/M)  

This error indicates the Ice tray has not returned to level after an ice harvest. 
The error is displayed after three failed attempts.

Replace I/M

COOL SELECT ZONE 
SENSOR

Cool Select Zone Sensor Error- open or short-circuit, connector failure. 
Cause is also a temperature reading > 122°or < -58 ° F

The voltage at MAIN PCB  Sensor 
betw een 4.5V~1.0V

R-DEFROSTING ERROR 

Refrigerator Room defrost heater- open or short-circuit, connector failure, or 
defective temperature fuse/bi-metal.  Defrost on over 80 minutes

Disconnect defrost connector 
from PCB,  check resistance

PANTRY-DAMPER-
HEATER ERROR 

Sensor system in Pantry Room errors

Disconnect heater connector 
from PCB,  check resistance

PANTRY-SENSOR ERROR

CR Room Sensor Error- This can be an open or short-circuit, contact failure. 
Cause is also a temperature reading > 122°or < -58 ° F.

The voltage of MAIN PCB Sensor 
betw een 4.5V~1.0V

I/M-SENSOR (F on Tw in 
I/M units) 

Ice Maker Sensor Error- open or short-circuit, connector failure. Cause is 
also a temperature reading > 122°or < -58 ° F

The voltage at MAIN PCB  Sensor 
betw een 4.5V~1.0V

I/M FUNCTION ERROR(F 
on Tw in I/M)  

This error indicates the Ice tray has not returned to level after an ice harvest. 
The error is displayed after three failed attempts.

Replace I/M

WATER HEATER ERROR 

Error is displayed w hen the w ater reservoir tank heater is open or shorted 

Disconnect heater connector 
from PCB,  check resistance

EXT-SENSOR 

Ambient Temp. Sensor Error- open or short-circuit, connector failure. Cause 
is also a temperature reading > 122°or < -58 ° F

The voltage at MAIN PCB Sensor 
betw een 4.5V~1.0V

F-SENSOR 

Freezer Compartment Sensor Error- open or short-circuit, connector failure. 
Cause is also a temperature reading > 122°or < -58 ° F

The voltage at MAIN PCB Sensor 
betw een 4.5V~1.0V

F-DEF-SENSOR 

Freezer Room Defrost Sensor Error- open or short-circuit, connector failure. 
Cause is also a temperature reading > 122°or < -58 ° F

The voltage at MAIN PCB Sensor 
betw een 4.5V~1.0V

F-FAN ERROR 

This error indicates the Freezer Evap. Fan is not spinning at the correct RPM 
or the fan feedback line is open.

Fan voltage at MAIN PCB  shall be 
betw een 7V~12V

C-FAN ERROR 

This error indicates the Condenser Fan is not spinning at the correct RPM or 
the fan feedback line is open.

Fan voltage at MAIN PCB  shall be 
betw een 7V~12V

FRENCH DOOR ICE ROOM 
SENSOR 

Ice Room Sensor Error- open or short-circuit, connector failure. Cause is also 
a temperature reading > 122°or < -58 ° F

The voltage at MAIN PCB Sensor 
betw een 4.5V~1.0V

F-DEFROSTING ERROR 

Freezer defrosting heater- open or short-circuit, connector failure, or 
defective temperature fuse/bi-metal.  Defrost on for over 80 minutes

Disconnect defrost connector 
from PCB,  check resistance

FRENCH DOOR ICE ROOM 
FAN ERROR 

This error indicates the Ice Room Compartment Evap. Fan is not spinning at 
the correct RPM or the fan feedback line is open.

Fan voltage at MAIN PCB  shall be 
betw een 7V~12V

ICE PIPE HEATER ERROR 

Error is displayed w hen the ice maker fill pipe heater is open or shorted. 

Replace Fill Tube Ass'y

Uart ERROR 
COMMUNICATION 

This error is not applicable, if the error is detected during diagnostic testing 
please ignore it.

No Repair Necessary

L↔M ERROR 
COMMUNICATION 

Communication error w ithin the Main PCB 

Replace main PCB

P↔M ERROR 
COMMUNICATION 

Communication betw een the Main PCB and Keypad 

Check w iring in door & cabinet, 
Panel PCB, Main PCB

Samsung 'Refrigerator' Diagnostic Code Quick Guide

Summary of Contents for RFG298AA**/XAA

Page 1: ...Saver Fridge simul taneously No sound when both buttons are pressed at the same time til it beeps and goes blank 8 12 seconds Publication tsRFG298AA Revision Date 03 30 2011 Component Value Chart Press Freezer button a second time to Force Mid Speed Run 3600RPM 2450RPM 2200RPM NOTICE Parts Change The interior lighting changed from incandescent lighting to LED lighting The new parts are NOT interch...

Page 2: ...ivity for 5 cycles 10 seconds off 3 seconds on the fan drive circuit is disabled for 10 minutes TO TEST THE FAN CIRCUIT VOLTAGE Power off and back on to check the DC voltage to the motor wait from 10 to 60 seconds for the fan voltage to kick in and then check fan voltage the average reading is 9 VDC If you get 3 seconds of voltage every 10 seconds for the 5 fan power up cycles then the Main PCB is...

Page 3: ... Sensor will check the temperature when it is lower than 1 5 for more than 5 minutes it will do a harvest with or without ice in the tray then fill with water 58 minutes after water is supplied to the Ice Tray the Ice Maker Sensor temperature will be checked When the Ice Maker Sensor maintains lower than 1 5 for 5 minutes it completes the harvest if the ice bin is not sensed as full Thermistor sen...

Page 4: ...e error is displayed after three failed attempts Replace I M WATER HEATER ERROR Error is displayed w hen the w ater reservoir tank heater is open or shorted Disconnect heater connector from PCB check resistance EXT SENSOR Ambient Temp Sensor Error open or short circuit connector failure Cause is also a temperature reading 122 or 58 F The voltage at MAIN PCB Sensor betw een 4 5V 1 0V F SENSOR Freez...

Page 5: ...30 2011 5 SERVICE BULLETIN PRODUCT Refrigerator BULLETIN NUMBER ASC20100714001 DATE 07 14 2010 Please review before ordering any parts CN78 1 3 Fz LED Blk Gry 4 7 FF LED Red Gry CN71 All 120vac 5 N Gry 9 Def Htr Common Org ...

Page 6: ...2 Red Blk 5vdc CN75 To Comp Inverter Board 1 CN76 1 Blk Gry 13vdc 2 CN76 1 Brn Gry 5vdc 4 3 Compressor control Org Red 2 2 8vdc CN79 2 7 Fill tube heater freezer Blu Wht 13vdc 3 7 Water Tank Htr Pnk Wht 13vdc CN30 Sensors Switches 1 5 Freezer Dr Sw Blk Gry 5vdc 1 5 Freezer Dr Sw Blk Gry 5vdc 2 CN50 7 R Door Sw Prp Gry 5vdc 3 CN76 1 F Sensor Red Gry 3 5 4 2vdc 4 CN76 1 F Def Sensor Org Gry 2 3 4 2v...

Page 7: ... tsRFG298AA RevC 03 30 2011 7 Late Production change ...

Page 8: ...nd check resistance to the windings Aproxametly10 ohms If not correct inspect wire harness if OK replace compressor 5 Disconnect CN02 SMPS PCB check resistance to Overload if open replace overload CN04 Compressor Control 2 CN40 4 5vdc Brn Gry 4 Comp Signal Org CN03 Compressor Windings 1 Compressor Blue 3 Compressor Prp 5 Compressor Wht CN02 Overload A C Line 1 OLP Brn 3 OLP S Blu 3 L Blk 1 N Red C...