Confidential
Chapter 2 Installing System
RFV01U-D1A Installation Manual v2.0
21
Copyright © 2017, All Rights Reserved.
Fixing Unit Bracket
There are two ways to fix a unit bracket to the RRH. One is fixing a unit mounting
bracket to the rear side of RRH (Standard installation). The other is fixing a unit
bracket to the side of RRH (Side installation). These are the same for the wall type
and pole type installation procedures.
To fix Unit Bracket_Standard Installation
1
Make sure that you have the following items:
Table 4.
Parts and Tools for fixing Unit Bracket_Standard installation
Category
Description
Parts
Unit bracket
1 EA/RRH
Fasteners
M6 × 35L Hex. Bolt
(washer assembly)
6 EA/RRH
Recommended Torque Value
M3 Screw
5.6 lbf·in (6.4 kgf·cm)
M6 Hex. Bolt
43 lbf
in (50 kgf·cm)
Working Tools
Torque Wrench (10~50 lbf
in), Torque Wrench Spanner head (apply Hex.
Head: 10 mm), Spanner (10 mm), Torque Driver (2~10 lbf
in), Screw Driver
Bit ('+', No. 2), Screw Driver ('+', No. 2)
2
Loosen a fastener of finger guard_rear and separate the dummy cover from it.
[Unit Bracket Standard Installation]
Unit Bracket
(RRH left)
Unit Bracket
(RRH rear)
[Unit Bracket Side Installation]