31
1) A defrost is determined based on the accumulated compressor on-time.
2) When the power is engaged for the first time, the defrost cycle for the freezer and the
refrigerator will begin after 4 hours of the accumulated compressor on-time.
3) A defrost interval depends on the ambient temperature, the number of door openings, and the
door open time.
4) A minimum interval is 6 hours and a maximum is 8 hours for the refrigerator, and 12 hours and
16 hours for the freezer, respectively.
5) The defrost heater on-time is determined by the defrost sensors as follow :
2. Product function
2-7. Defrosting Function
Refrigerator
Freezer
Heater ON
Below 50 (10
)
℉
℃
-
Heater OFF
62 (17
)
℉
℃
50 (10
)
℉
℃
Summary of Contents for RS277ACPN
Page 14: ...15 1 7 Dimensions of Refrigerator inches 1 Product Information...
Page 17: ...18 1 10 Cooling Air Circulation 1 Product Information Freezer Refrigerator...
Page 70: ...71 5 1 Block diagram 5 Circuit Descriptions Double Click...
Page 71: ...72 5 2 SCHEMATIC DIAGRAM 5 Circuit Descriptions Double Click...
Page 72: ...73 5 3 WIRING DIAGRAM 5 Circuit Descriptions Double Click...
Page 74: ...75 5 5 CONNECTOR ARRANGEMENT Main Board 5 Circuit Descriptions Double Click...
Page 87: ...88 5 17 Load Drive Circuit 5 Circuit Descriptions Double Click...
Page 92: ...93 6 Reference Information 6 2 Model name nomenclature...