4
2. ELECTRICAL PART SPECIFICATIONS & STANDARD
220V/50~60Hz
MK183H-L2U MK172H-L2U
230~240V/50Hz
MK183Q-L2U MK172Q-L2U
127V/60Hz
MK162P-S1U
110~115V/60Hz
MK162C-L1U
RT53EA,RT49EA
RSCR
R-134a (160G)
Freol
α
-10c(Ester), 265cc
Split Fin & Tube Type
Forced & Natural Convection Type
Molecular Sieve XH-9
ID0.75 X L3000
BSBN (Brass Screw)
Sub-Condenser
Dryer
Capillary tube
Ground screw
Model
Starting type
Refrigerant
Oil Charge
Freezer
Evaporator
Compressor
STANDARD
ITEM
Model
Voltage & Frequency
2-1) Semi Electronic model
ITEM
STANDARD
Freezer
Type
F-Sensor
Type
Damper-Thermo
ON(
℃
)
–15
℃
–18
℃
–21
℃
–24
℃
OPEN(
℃
)
14
℃
10
℃
6
℃
20
℃
Temperature Selection
L : –16
℃
M : –19
℃
H : –22
℃
ULTRA: –25
℃
Temperature Selection
COLD
NORMAL
COLDER
VACATION
OFF(
℃
)
–17
℃
–20
℃
–23
℃
–26
℃
CLOSE(
℃
)
3
℃
-1
℃
-5
℃
9
℃
Refrigerator
T
emperature
Thermal Fuse for Preventing Over
Heating of Freezer Defrost Heater
Min (8H R)
10
±
2min
THERMISTOR (502AT)
SPEC (5.0K
Ω
/
25
℃)
Defrosting
Sensor
Fuse
(Bimetal)
Defrost Cycle
Pause Time
Freezer-Sensor
Freezer Evap-Sensor
Ambient TEMP-Sensor
Electrical par
ts
AC250V/10A
ON(40
℃
)/OFF(60
℃
)
www.electronicsmarket.com.au
www.electronicsmarket.com.au