background image

INTRODUCTION & INFORMATION 

Introduction 

 

The  UWB(Ultra Wide  Band)  sensors  refers  to  a  kind  of  radar  technology  that  was  traditionally 
used  in  military  applications.  When  used  as  a  security  means, 

it’s  low  power,  wide  band 

characteristics  often  causes  frequent  false  alarms.  Overcoming  such  limitations  with  its 
excellence in technology, S1 showcases the first ever UWB-based security sensor in the world. 
Its  radar-based  principle  makes  it  inherently  immune  to  heat  source-induced  false  alarms  and 
enables  high  level  of  sensitivity  to the movement  of heat-insulated  intruders.  Coverage  can  be 
flexibly adjusted to enable its deployment in various environments. 
 
This  document  describes  the  features  and  the  specifications  of  the  UWB  sensor,  important 
regulatory information concerning its use, and details on how to diagnose potential problems. 

Information to the User 

 
The UWB sensor is an ultra-wideband(UWB) wireless device certified under FCC Part 15.517. 
It’s use is subject to technical requirements for indoor UWB systems, in particular the stipulation 
that  the  devices  must  only  be  used  indoors.  Users  should  note  carefully  the  following 
information: 
 
    

• CAUTION: This equipment may only be operated indoors. Operation outdoors is in 

      violation of 47 U.S.C. 301 and could subject the operator to serious penalties. 
 
    

• This device complies with Part 15 of the FCC Rules. Operation is subject to the following 

       two conditions: (1) this device may not cause harmful interference, and (2) this device must 
      accept any interference received, including interference that may cause undesired operation. 
 
Users should also carefully note the following information: 
 
    

• CAUTION: Any changes or modifications made to the “UWB Sensor” which are not        

      expressly approved by the 

“S-1” could void the user’s authority to operate the equipment. 

 
    

• NOTE: This equipment has been tested and found to comply with the limits for a Class B 

      digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide 
      reasonable protection against harmful interference in a residential installation This 
      equipment generates, uses and can radiate radio frequency energy and, if not installed and 
      used in accordance with the instructions, may cause harmful interference to radio 
      communications, However, there is no guarantee that interference will not occur in a 
      particular installation. If this equipment does cause harmful interference to radio or 
      television reception, which can be determined by turning the equipment off and on, the user 
      is encouraged to try to correct the interference by one or more of the following measures: 
      - Reorient or relocate the receiving antenna. 
      - Increase the separation between the equipment and receiver. 
      - Connect the equipment into an outlet on a circuit different from that to which the receiver 
        Is connected. 
      - Consult the dealer or an experienced radio/TV technician for help. 

- 1-                                                                   UWB Intrusion Detection Sensor 

– URX-P01 

Summary of Contents for S-1 URX-P01

Page 1: ...t Group S 1 CORPORATION 168 S1 BUILDING SOONHWA DONG JOONG GU SEOUL KOREA Tel 82 1588 3112 Fax 82 2 2131 8869 Website www s1 co kr Revised May 2015 CAUTION This equipment may only be operated Indoors Do not use to Outdoors Do not intentionally install aimed at windows or outside opening doors ...

Page 2: ...Table of Contents Introduction Information 1 Features of the UWB Sensor 2 Coverage of the UWB Sensor 3 UWB Sensor Specifications 4 Installation 5 Operational precautions 7 ...

Page 3: ...C Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Users should also carefully note the following information CAUTION Any changes or modifications made to the UWB Sensor which are not expressly approved by the S 1 could void th...

Page 4: ... LED GB 41 Bracket SET Terminal Power COM Tamper Rotary Switch Label System TOP BOTTOM Magnetic Switch Point Features of the UWB Sensor The diagram below shows several important features of the UWB Sensor 2 UWB Intrusion Detection Sensor URX P01 ...

Page 5: ...2 4m 6ft 3 0m 8ft 10ft 5m 16 4ft 10m 32 8ft 2m 6 5ft Note Installer is to walk into the pattern or may walk perpendicular to the pattern to verify the pattern Coverage of the UWB Sensor Maximum detection area of the sensor is as follows 3 UWB Intrusion Detection Sensor URX P01 ...

Page 6: ...m Indicator Red LED ON When detecting Tamper Parameters N C 200VDC 0 1A max Alarm Output Period 2 Sec Alarm Output N C 60VDC 0 6A max Warm up Period Approx Under 10 sec Power Supply 12VDC 9 6 14 4VDC Current Consumption 20mA max at 12VDC 9 6 14 4VDC Weight 85g 2 99oz Operating Temperature 10 50 14 122 Operating Humidity 95 max UWB Sensor Specifications The specification of the sensor refer to the ...

Page 7: ...INSTALLATION 2 Step Assemble Bottom and GB 41 3 Step Connection Top and Wire 1 Step Using key separate TOP and BOTTOM SPARE TAMPER ALRAM 12VDC NC C SP NC C 5 UWB Intrusion Detection Sensor URX P01 ...

Page 8: ...s only a part of a complete system we cannot responsibility any damage to change without prior consent of the S 1 Specifications and design are subject to change without prior notice 6 UWB Intrusion Detection Sensor URX P01 Adjustable detection range from 1 to 10 meter by rotary switch Note that each adjusted range has 0 5m deviation Be sure walk test after installation Switch Direction 0 1 2 3 4 ...

Page 9: ...s and cats When swaying objects mobiles of metal material in the detection area change the direction or adjust the detection distance Do not install in the swaying wall Do not install the outdoor Do not install the curtain blind by the external wind swaying Do not install near any moving fan 7 UWB Intrusion Detection Sensor URX P01 ...