SAMSUNG Proprietary-Contents may change without notice
4-1
4. NAM Programming
4-1 NAM programming
Programming of all NAM parameters, e.g. Service Security Code, MCC, MNC, MIN#, CDMA Channel#,
vocoder rate, MOB_TERM, SID, SID/NID pairs, Slot Cycle Index, etc.
1) Press “Menu 6,
∗
” Enter SPC Code “000000” Use Right navigation key to select items to program.
2) You can select MORE (Menu) when “Basic NAM 1 programming is complete.” displays. Select if you want
to program more detailed items than shown in basic NAM programming. Press OK to save or Right
navigation key to proceed to next item.
-> MORE programming not a required for NAM programming.
3) To toggle between settings, e.g. Home SID/NID pairs or selecting between Yes/No, use the Up/Down
navigation key:
A. For changing Home SID/NID pairs, select from SID/NID pair numbers 01 to 20 by pressing Up
navigation key Press [edit] by pressing Menu key to change setting Press OK key to save setting.
B. For changing Forn SID or NID Registration, Home Sys. Registration, etc. press Up/Down navigation
key to select between Yes or No. Press OK key to save setting.
4) Press End Key to save & exit NAM programming.
4-2 Field Debug Screen and Test Calls
1) Press “Menu 0,
∗
” Enter “000000” ;
1 ; Debug Screen
2 : Test Calls:
Markov New 8K, Markov New 13K, Loop Back 8K, Loopback 13K,
TDSO Call Simple, TDSO Full
2) Repeat above 1) to exit Debug screen
4-3 A-Key programming via Keypad
1) Press “Menu 6,
∗
” Enter SPC Code “000000” Menu (Soft key) - then you will see “Press[AKEY] to continue
AKEY: “ Menu ([AKEY] ) Enter the 20-digit AKEY. Press “OK” Key to save value.