28_ Setup
Setup
COMM ADJ (Communication Adjustment)
: This function sets up the camera
communication status when controlling the camera through an external control device.
➊
When the SPECIAL menu screen is
displayed, press the Function Setup
switch so that the arrow indicates
‘COMM ADJ’.
➋
Set up the mode using the Function
Setup witch.
CAM ID : Determines the camera's
identifi cation number
(between 0 and 255).
BAUD RATE : You can select 2400/48
00/9600/19200/38400/57600 bps.
UART MODE : You can select NONE, EVEN or ODD for the parity bits.
RET PKT : Determines whether to send a command back to the controller device
when a communication control command is sent to the camera.
DISP ID : Display camera ID on top left corner of the screen.
PROTOCOL : You can select one of various protocols. SAMSUNG-T,
SAMSUNG-E, PELCO-D , PELCO-P, BOSCH, HONEYWELL,
VICON, PANASONIC, GE, AD.
y
-
-
-
-
-
-
COMM SETUP
䯝
1. CAM ID
Â
IIIIIIIIIIIIIIIIIIIIIIIIIIIII
1
3. UART MODE
8-N-1
4. RET PKT
ENABLE
5.
DISP
ID
OFF
6.
PROTOCOL
SAMSUNG-T
7.
Initial value of communication adjustment
Item
Camera ID
BAUD RATE
UART MODE
PET PKT
Initial value
½
1
9600
8-N-1
ENABLE
RETURN
2. BAUD RATE
9600
EXIT
Select a desired EXIT mode using the Function Setup switch depending on the camera purpose.
sAVe
: Save the current settings and exit the MAIN SETUP menu.
NOT sAVe
: Do not save the current settings and exit the MAIN SETUP menu.
ReseT
RETURN : Select this to save the SPECIAL menu settings and return to the MAIN
SETUP menu.
: Resets the camera settings to the factory defaults. Monitor, Language
and COAX settings are not initialized.