76_
setup
setup
Connecting the power connector and GND incorrectly to the NC/NO and COM ports may cause a short circuit and fi re,
damaging the camera.
The max voltage and capacity of the Alarm OUT/AUX OUT ports are 30VDC/2A and 24VAC/2.5A.
Operating the camera beyond the capacity may decrease the camera’s lifespan and damage it.
MD Dwell Time
When Motion Detection under the Preset Edit menu is selected,
MD Dwell Time performs the Tour or Group function.
While the camera is performing a sequence action, if motion is
detected from a selected preset location, the camera pauses the
sequence action operation and starts monitoring the location instead
for a duration that is set under the MD Dwell Time menu.
If the motion is no longer detectable or the duration expires, the
camera aborts the monitoring operation and then resumes the
sequence action.
ALM Dwell Time
You can specify the time of sequence operation that will be activated if an event occurs from the alarm
input.
SET:
The sequence operation will proceed for a specifi ed time.
HOLD:
The sequence operation will be maintained until the user deactivates it.
M
z
z
Main
Menu
Camera
Setting
Sequence
Setting
P/T
Setting
OSD
Setting
Alarm
Setting
Initialize
Password
Setting
Status
Æ
Alarm
Setting
Alarm
Enable
OFF
Alarm
Input
Alarm/AUX
Output
MD Dwell Time
OFF
ALM Dwell Time HOLD