3. Disassembly and Reassembly
Service Manual
SCX-483x/5x3x series
3-24
Samsung Electronics
3.3.18 Regi. / Feed / Empty sensor
1. Remove the cassette and duplex unit.
2. Remove the PLATE-FRAME BOTTOM after
removing 4 screws.
3. Remove the sensor cover after removing 2
screws.
4. For the sensor to require replacement, unplug
the connector then replace it.
5. Remove the sensor cover after removing
2 screws.
Feed sensor
Regi. sensor
Feed sensor
Regi. sensor