COLOR CCD CAMERA
User Guide
34
COLOR CCD CAMERA
User Guide
35
Operating Your Camera
Select a desired EXIT mode using the Function Setup switch depending on the camera
purpose.
- SAVE
: Save the current settings and exit the MAIN SETUP menu.
- NOT SAVE : Do not save the current settings and exit the MAIN SETUP menu.
- RESET
: Resets the camera settings to the factory defaults. Communication,
Language and Monitor settings are not initialized.
EXIT
Troubleshooting
If you have trouble operating your camera, refer to the following table.
If the guidelines do not enable you to solve the problem, contact an authorized technician.
●
Nothing appears on the screen.
▶
Check that the power cord and line connection between the camera and monitor are fixed
properly.
▶
Check that you have properly connected UTP cable or BNC cable to the camera.
▶
Check the type of lens.
▶
Check the pin arrangement for the UTP cable.(EIA/TIA-568B)
●
The image on the screen is dim.
▶
Is lens stained with dirt? Clean your lens with soft, clean cloth.
▶
Set the camera to the correct monitor setting.
▶
If the camera is exposed to too strong light, change the camera position.
●
The image on the screen is dark.
▶
Adjust the contrast feature of the monitor.
▶
If you have an intermediate device, set the 75
Ω
/ Hi-z properly.
●
The camera is not working properly, and the surface of the camera is hot.
▶
Check that you have properly connected the camera to an appropriate power source.
●
The SENS-UP function does not work.
▶
Check that AGC of EXPOSURE SETUP menu is ‘OFF’.
▶
Check that SHUTTER of EXPOSURE SETUP menu is ‘A.FLK’ or ‘MANUAL’.
●
The Motion Detection function does not work.
▶
Check that MOTION DET of SPECIAL SETUP menu is ‘OFF’.
●
Color is not correct.
▶
Check the setting of WHITE BAL SETUP menu .
●
The screen flickers continually.
▶
Ensure the camera is not pointing towards the sun.
●
When coaxial communication is not available:
▶
Make sure that the camera and monitor are installed within the recommended distance.
▶
Use the video amplifier equivalent to coaxitron if the recommended installation distance is exceeded.
●
Picture is distorted.
▶
Check the length of the UTP cable (1km or less).
●
The camera does not work, and the video feed from the camera is not being received.
▶
Check the Junction Box to see whether the connection status and pin arrangement for the
camera's UTP cable and the Camera Input UTP cable are normal.
LANGUAGE : You can select the menu language according to your requirements.
RETURN : Select this to save the SPECIAL menu settings and return to the MAIN
SETUP menu.
- CAM ID : Determines the camera's identification
number (between 0 and 255).
- BAUD RATE : You can select 2400/4800/9600/19200/
38400/57600 bps.
- UART MODE : You can select NONE, EVEN or ODD for
the parity bits.
- RET PKT : Determines whether to send a command
back to the controller device when a
communication control command is sent to the camera.
- DISP ID : Display camera title on top left corner of the screen.
- PROTOCOL : Select the communication PROTOCOL.
(STW(SPD)/PELCO-D/PELCO-P/BOSCH/HONEYWELL/VICON/SEC/
PANASONIC)
- RETURN : Select this to save the PRIVACY menu settings and return to the SPECIAL menu.
* Initial value of communication adjustment
Item
Camera ID
BAUD RATE UART MODE
PET PKT
Initial value
1
9600
8-NONE-1
ENABLE