SAMSUNG Proprietary-Contents may change without notice
Flow Chart of Troubleshooting and Circuit Diagrams
3-40
This Document can not be used without Samsung's authorization
3-2-5. PCS Receiver
Rx ON
RF Input : 661Ch
Cell Pwr : -50dBm
YES
Normal condition
Catch the channel
NO
NO
RFSW100(RF Switch)
Pin#3
≥
-60dBm ?
END
Check the UCP300
YES
NO
Check Intenna Soldering
ANTCON100, ANTCON101
Resolder or change RFSW100
FEM100
Pin#9,11 = LOW &
Pin#10 = HIGH ?
Resolder or change FEM100
Check FEM100 control path
NO
YES
U100
Pin#24,35
≥
-60dBm ?
FEM100
Pin#16,17
≥
-60dBm ?
NO
Check & resolder U100
YES
YES
YES