SAMSUNG Proprietary-Contents may change without notice
Flow Chart of Troubleshooting and Circuit Diagrams
3-41
This Document can not be used without Samsung's authorization
3-2-6. PCS Transmitter
Tx ON
RF Level : 0
YES
Normal condition
Catch the channel
NO
NO
RFSW100(RF Switch)
Pin#1
≥
27dBm ?
END
Check the UCP300
YES
NO
Check Intenna Soldering
ANTCON100, ANTCON101
Resolder or change RFSW100
Check R104, R108
Resolder or change VCO100
FEM100
Pin#9 = HIGH &
Pin#10,11 = LOW ?
Resolder or change FEM100
Check FEM100 control path
NO
YES
VCO100
Pin#5
≒
6dBm ?
PAM100
Pin#16
≥
27dBm ?
FEM100
Pin#20
≥
27dBm ?
Check C137, C139
≥
1V ?
NO
Check C105, C106, C157, L103
Resolder or change PAM100
Check Loop filter circuit
C129, C131, C132, R111, R112
NO
NO
YES
YES
YES
YES