COLOR DOME CAMERA
User’s Manual
14
COLOR DOME CAMERA
User’s Manual
15
Operating Your Camera
• As shown in the table above, voltage decreases as the wire gets longer. Therefore
use of an excessively long adaptor output line for connection to the camera may
affect the performance of the camera.
*Standard voltage for camera operation : AC 24V ± 10%, DC 12V ± 10%
*There may be some deviation in voltage drop depending on the type of wire and the manufacturer.
• Be sure to connect power only after all the installation is complete.
• Note that AC / DC adaptor is not supplied with camera.
• Ground should be connected to the GND terminal.
Notes
When the resistance value of copper wire is at [20˚C(68˚F)]
Connecting to RS-485 Control Cable
Using a RS-485 communication, it will be able to control the OSD menu at the
SAMSUNG TECHWIN System Controller or DVR.
(1) The case which it controls from the PC
Using a RS-485 converter, It connects to RS-485 control cable outside camera and
serial cable
EX) SERIAL PORT OF THE PC(COM1)
→
SERIAL CABLE
→
RS-485 CONVERTER
→
RS-485 CONTROL
CABLE
(2)The case which it controls from the DVR or System Controller
It connects the RS-485 control cable in the connection terminal of 485 control boards
which are connected with the DVR or System Controller.
• When you construct external control systems for a camera control, please use to the
SAMSUNG TECHWIN PROTOCOL or PELCO-D PROTOCOL.
• When you connecting to RS-485 control cable, please peel off the outer skin inside the
RS-485 control cable.
• In case of SCC-101 connection, change communication mode to
『
8-E-1
』
at
『
Communication
configuration
』
menu. (For more information, refer to SCC-101 manual.)
Notes
* RS-485 Communication establishment initial value
Menu Configuration
Copper wire size (AWG)
#24(0.22mm
2
)
#22(0.33mm
2
)
#20(0.52mm
2
)
#18(0.83mm
2
)
Resistance (Ω/m)
0.078
0.050
0.030
0.018
Voltage Drop (V/m)
0.028
0.018
0.011
0.006
Item
Camera ID
BAUD RATE
UART MODE
PET PKT
Initial value
1
9600
8-NONE-1
ENABLE
Setup Menu
LENS
●
DC
EXPOSURE
●
SHUTTER
●
AGC
●
SENS-UP
●
RETURN
WHITE BALANCE
●
ATW
●
MANUAL
●
AWC
→
SET
●
OUTDOOR
●
INDOOR
BACKLIGHT
●
OFF
●
BLC
●
HLC
SSNR
●
ON
●
OFF
DAY/NIGHT
●
COLOR
●
B/W
●
AUTO
IMAGE ADJUSTMENT
(IMAGE ADJ.)
●
V-REV
●
H-REV
●
D-ZOOM
●
SHARPNESS
●
RETURN
SPECIAL
●
CAMTITLE
●
SYNC
●
MOTION DET
●
PRIVACY
●
DIS
●
COMM ADJ
●
LANGUAGE
●
RESET
●
RETURN
EXIT
Connection
485 Control Board Connection Port
RS-485 Control Port
(+) CONNECTION TERMINAL
RED (TRX+)
(- ) CONNECTION TERMINAL
WHITE (TRX-)
CONTROL CABLE
SPEC
RED (TRX+)
RS-485+
WHITE(TRX-)
RS-485-
RS-485 communication control