4. Troubleshooting
► Error Code
A3–3210
A3–3211
A3–3212
► Error message
Sensor Failure: #A3-3210. Turn off then on. Call for service if the problem persists
Sensor Failure: #A3-3211. Turn off then on. Call for service if the problem persists
Sensor Failure: #A3-3212. Turn off then on. Call for service if the problem persists
► Symptom
Inner temperature sensor is defective.
► Troubleshooting method
•
A3–3210 : Inner temperature sensor value is abnormal.
•
A3–3211 : Inner temperature sensor is in short status.
•
A3–3212 : Inner temperature sensor is in open status.
1) Turn the machine off then on.
2) Check the connection between the inner temp sensor and main board. If the connection is OK, replace the inner
temp sensor .
3) If the sensor is normal, replace the main board.
Copyright© 1995-2013 SAMSUNG. All rights reserved.
4-94