4. Troubleshooting
► Error Code
A3–3310
A3–3311
A3–3312
A3–3410
A3–3411
A3–3412
► Error message
Sensor Failure: #A3-3310. Turn off then on. Call for service if the problem persists
Sensor Failure: #A3-3311. Turn off then on. Call for service if the problem persists
Sensor Failure: #A3-3312. Turn off then on. Call for service if the problem persists
Sensor Failure: #A3-3410. Turn off then on. Call for service if the problem persists
Sensor Failure: #A3-3411. Turn off then on. Call for service if the problem persists
Sensor Failure: #A3-3412. Turn off then on. Call for service if the problem persists
► Symptom
Outer temperature/humidity sensor is defective.
► Troubleshooting method
•
A3–3310 / A3–3311 / A3–3312 : Temperature function is abnormal.
•
A3–3410 / A3–3411 / A3–3412 : Humidity function is abnormal.
1) Turn the machine off then on.
2) Check the connection between the outer temp sensor and main board. If the connection is OK, replace the outer
temp sensor .
3) If the sensor is normal, replace the main board.
4-95