4. Troubleshooting
► Error Code
C8–3130
► Error message
Replace with new magenta developer unit
► Symptom
The life of the magenta developer unit expires has expired.
► Troubleshooting method
1) Turn the machine off.
2) Replace the magenta developer unit.
3) Turn the machine on then print the test page.
► Error Code
C8–3210
C8–3310
C8–3313
► Error message
Magenta Developer Failure: #C8-3210. Turn off then on
Magenta Developer Failure: #C8-3310. Install magenta developer unit again
Magenta Developer Failure: #C8-3313. Turn off then on. Please call for service if the problem persists
► Symptom
The magenta developer unit has a problem with toner supply or sensor calibration.
► Troubleshooting method
1) Open the front cover. Then, remove the waste toner container.
2) Check if the toner supply pipe is blocked. If it is closed, open it. (Lever is in horizontal position.)
3) Check if deve unit connector(4 pin) is connected correctly. Check if the pin is deformed.
4) Install the waste toner container. Close the front cover.
5) Turn the machine off then on.
6) If the problem persists, remove and reinstall the magenta developer unit.
7) If the problem persists, replace the magenta developer unit.
Copyright© 1995-2013 SAMSUNG. All rights reserved.