Level 3 Repair
Distribution, transmission, or infringement of any content or data from this document without Samsung’s written authorization is strictly prohibited.
Confidential and proprietary-the contents in this service guide subject to change without prior notice.
8-27
8-3-11. GSM900/GSM1800 TX
CONTINUOUS TX ON CONDITION
TX POWER IDX1 APPLIED
GSM850 CH : 190
DCS1800 CH : 698
RBW : 100KHz
VBW : 100KHz
SPAN : 10MHz
REF LEV. : 10dBm
ATT. : 20dB
Check C103 :
About 30dBm ?
Yes
No
END
Check soldered or change
C100, C101, F106, C174,
RFS100, L100, L129, C109
Check component
soldering status OK at
U100, U104
Check soldered or change U100, U104
Yes
No
GSM900/1800 Transmitter
is OK?
Check soldered or change UCP300
Yes
No