8. Level 3 Repair
8-4-11. 5M CAMERA
Check the camera
connector on main PBA
Check the voltage When 5M
camera is operating
C7055 = 2.8V
Reconnect the HD7002
Replace Camera module
Or check the U7004
NO
Ab
YES
NO
Ab
YES
End
Check C7043
(Clock frequency) is 26Mhz
※
Test condition
(oscilloscope setting)
:10.0ns/div(time division)
Check or replace U400
NO
Ab
YES
YES
Replace the camera module
Check the voltage When 5M
camera is operating
C7042 = 1.8V
Replace Camera module
Or check the U7007
NO
Ab
YES
Check the voltage When 5M
camera is operating
C7056 = 1.2V
YES
Replace Camera module
Or check the U7005
NO
Ab