Ver.
CHAPTER 2. Installation of RRH-P4
2-42
© SAMSUNG Electronics Co., Ltd.
2600-00CTEIGAA
4.0
13) Insert the rain protection filler completely to cable gland body and fasten the cable
gland nut by torque 2.17 lbf.ft (30 kgf.cm) using torque wrench. After fixing nut,
confirm using the gap gauge that distance between cable gland body and nut is within
0.03 in. (1.0 mm).
Figure 2.32 Connecting RRH-P4 power cable (AWG8) (6)
Power Cable
(Hybrid cable, AWG8, 2C)
Rain Protection Filler
Cable Gland Nut
External Power Cable Support Bracket
Power Cable Outer Jacket
(AWG8)
Cable Gland Nut
Gap: 0.03 in.
Gap Gauge
Rain Protection Gasket
* Insert cable when the unsheathed DC power cable outer jacket locate at the rain protection filter
protrusion.
Rain Protection Filler
Protrusion