SMH1816 

2/17/2012 

1

Fast Track Troubleshooting 

Publication #  rsSMH1816   Revision Date 1/19/2012

 

Model: SMH1816***/XAA  

 

IMPORTANT SAFETY NOTICE

 – 

“For Technicians Only”

  This service data sheet is 

intended for use by persons having electrical, electronic, and mechanical experience 
and knowledge at a level generally considered acceptable in the appliance repair trade.  
Any attempt to repair a major appliance may result in personal injury and property 
damage.  The manufacturer or seller cannot be responsible, nor assume any liability for 
injury or damage of any kind arising from the use of this data sheet. 

SUPPORT INFORMATION 

Training — Plus One 

http://my.plus1solutions.net/clientPortals/samsung/ 

Help — GSP

http://gspn3.samsungcsportal.com

 

Samsung Product Support TV 

http://support-us.samsung.com/spstv/howto.jsp 

Customer information videos and chat programs. Programs for Fridges, Laundry, Ranges & D/W 

Oven Thermal Cutout 

The oven thermal cutout (Cavity TCO) is located on the top side of the oven cavity beside the exhaust duct with a tem-
perature rating of 248°F (120°C) and is 

NOT

 resettable. 

Hood Thermal Cutout 

This cutout will protect the touch control from excessive heat by turning the vent fan on at low speed. If the surface units 
of the range are used for long periods of time heat will build up and could damage the microwave control. In order to pre-
vent this, a thermal cutout is installed on the duct behind the control. This cutout will close (158°F/70°C - vent fan ener-
gized) and open (104°F/40°C - vent fan de-energized) depending on temperature. 

Magnetron Thermal Cutout 

The magnetron thermal cutout is located above the leads to the magnetrons. It is designed to prevent damage to the 
magnetron if an overheated condition develops in the tube due to cooling fan failure, obstructed air ducts, dirty or 
blocked air intake. Under normal operation, the magnetron thermal cutout remains closed. However, when abnormally 
high temperatures are reached within the magnetron, the magnetron thermal cutout will open at 302°F (150°C) causing 
the oven to shut down. After the temperature drops to 140°F (60°C) it will reset and cooking will be able to resume. 

Bottom Thermal Cutout 

During a fire on the stove the heat could be intense enough to close the Hood Thermal Cutout and force the fan to run. 
While at moderate high temperature we do want it to run, however during a fire it is advantageous to NOT have the vent 
fan running. So if a fire were to start on the stove top the Bottom Thermal Cutout would open at 248°F (120°C) and re-
move all power to the microwave oven.  This cutout is 

NOT

 resettable. 

Error Code 

Cause and countermeasure 

-SE- 

Key short error (10 sec.).  Replace assy. control 
panel or smart board. 

E-11 

Sensor open error.  Check unplugged sensor, wiring 
or smart board.  If necessary, replace sensor. If 
error code appears when starting sensor function, 
replace smart board. 

E-12 

Sensor short error. Check shorted sensor or smart 
board.  If necessary, replace sensor.  If error code 
appears when starting sensor function, replace 
smart board. 

E-13 

Sensor T1 max time error. Check sensor.  If neces-
sary, replace sensor.  If error code appears when 
starting sensor function, replace smart board. 

SENSOR TEST (QUICK TEST) 
1. With 2 fingers touch and hold the following pads at 
the same time: 

Auto Defrost and Popcorn 

2. Observe diagnostic number in display (Numbers 
approximate). 
● 15-185 (Normal-verify with “detection test” ) 
● 213 or Higher (Sensor failed to open, sensor un-
plugged, wiring or smart board). 
● Less than 6 (shorted sensor or smart board). 

NOTE

: Only heater terminals (Black and Red leads) 

can be checked with an ohmmeter (30Ω). 

CAUTION

: DO NOT ATTEMPT TO CHECK SENSOR 

TERMINALS (White and Orange leads). 
♣ CAN DAMAGE SENSOR. 

TO TEST BLOWER WINDINGS:  

1. 

Disconnect power and remove grill.  

2. 

Open control panel and discharge 

capacitor.  

3. 

Continuity test across the two wires of the run capacitor should be approximately 100 ohms of resistance. 

This test allows you to read across all three windings at the same time.  Thermal protector reads 0 ohms from white to 
orange.

 

SMH1816B/XAA  DE94-02517A 

SMH1816W/XAA  DE94-02517B 

SMH1816S/XAA  DE94-02517C 

SE error.  

Switch membrane not 

available.  Order Control Panel