Procedure for measurement of microwave energy leakage 

 

1.   Pour 275±15cc of 20±5°C(68±9°F) water in a beaker which is 

graduated to 600cc, and place the beaker in the center of the oven  

2.  Start to operate the oven and measure the leakage by using a mi-

crowave energy survey meter. 

3.  Set survey meter with dual ranges to 2,450MHz.  

4.  When measuring the leakage, always use the 2 inch spacer cone 

with the probe.   Hold the probe perpendicular to the cabinet door. 
Place the spacer cone of the probe on the door and/or cabinet door 
seam and move along the seam. The door viewing window and the 
exhaust openings moving the probe in a clockwise    direction at a 
rate of 1 inch/sec. If the leakage testing of the cabinet door seam is 
taken near a corner of the door, keep the probe perpendicular to 
the areas making sure that the probe end at the base of the cone 
does not get closer than 5 cm to any metal. If if gets closer than 5 
cm, erroneous readings may result. 

5.  Measured leakage must be less than 4mW/cm2 after repair and 

adjustment.  

Maximum allowable leakage is 5mW/cm2. 4mW/cm2 is used to allow 
for measurement and meter accuracy. 

Microwave Cooking Wattage Test

  

Safety precautions  

High Voltage Warning 

Do not attempt to 

measure any of the high voltages --this in-
cludes the filament voltage of the magnetron. 
High voltage is present during any cook cycle. 
Before touching any components or wiring, 
always unplug the oven and discharge the 
high voltage capacitor 

Some semiconductor (―solid state‖) devices 
are easily damaged by static electricity. Such 
components are called 

Electrostatically    

Sensitive Devices (ESDs). 

Examples            

include integrated circuits and field-effect 
transistors. Immediately before handling any                 
semiconductor components or assemblies, 
drain the electrostatic charge from your body 
by touching a known earth ground. 

Temp Rise

 

Output

 

Temp Rise

 

Out-
put

 

5

 

194

 

23

 

891

 

6

 

232

 

24

 

930

 

7

 

271

 

25

 

969

 

8

 

310

 

26

 

1007

 

9

 

349

 

27

 

1046

 

10

 

387

 

28

 

1085

 

11

 

426

 

29

 

1124

 

12

 

464

 

30

 

1162

 

13

 

504

 

31

 

1201

 

14

 

542

 

32

 

1240

 

15

 

581

 

33

 

1279

 

16

 

620

 

34

 

1317

 

17

 

659

 

35

 

1356

 

18

 

697

 

36

 

1395

 

19

 

736

 

37

 

1434

 

20

 

775

 

38

 

1472

 

21

 

814

 

39

 

1511

 

22

 

852

 

40

 

1550

 

Fill a 1000ml plastic room temperature container with cool tap water, 

temperature of the water should be 55-65 degrees  

Stir water with a thermometer and record the water temperature, remove 

thermometer.  

Place the container in the center of the lowest shelf or center of the    

bottom of the microwave.  

For units less than 1550 watts, operate the oven on high for exactly 63 

seconds.  

Using the thermometer, stir the water to check the temperature of the 

water.  

Subtract the starting temperature from the final temperature; this will be 

the temperature rise.  

 

NOTE: Check line voltage under load, lower line voltage will lower 
the power output.

 

M/W Information 

Specifications 

M/W Power 

1100 Watts 

M/W Weight 

54.23 Lbs 

High Voltage 

Transformer 

Primary 

0.43Ω 

Secondary 

125-130Ω 

Filament 

0.0Ω 

Motors 

Vent Turbo 

21Ω 

Vent High 

45Ω 

TT & Stirrer Motors 

120Ω 

Fan Motor 