NETWORK PTZ CAMERA
User Guide
18
Chapter 3. Installing Camera & Network Setup
*Note
- To use a third party controller with this product, please contact our After-Sales Service or
Technology
Department.
- AD Protocol Control Method
1. Input Camera OSD: 3+Auxiliary ON
2. Output Camera OSD: 3+Auxiliary OFF
3. Enter: IRIS Open
4. Esc: IRIS Closed
- For more information about the protocols, please refer to our official website.
Select a communication method for the camera.
Select a communication response method for the camera and controller: Response or No
Response.
To prevent the attenuation of communication signals between the camera and controller,
cameras that are a long distance from the camera and controller communication loop must
be set up with the proper termination settings.
Function
ON
OFF
SW2- #3
Transfer Mode Switch
RS-422(4Wire)
RS-485(2Wire)
Function
ON
OFF
SW2- #4
SW2- #4
Response Mode Switch
No Response
Camera Input Position
SW3- #2
SW3- #3
Longest Distance Terminal
ON
ON
In the Middle of the Loop
OFF
OFF
t
Communication Method Settings
t
Communication Response Settings
t
Termination Settings
ö
Factory Release Mode: RS-485(OFF)
ö
Factory Release Mode: No Response(OFF)
ö
Factory Release Mode: In the Middle of the Loop (OFF/OFF)