English
17
Connection & Control
TO CONTROL THE CAMERA USING RS-485 SIGNAL
OUTPUT VIA RS-232 COMMUNICATIONS
Connect the product to DC 12V power source or insert 4 AA-sized
batteries into the battery compartment.
(Power can be supplied via USB cable connection.)
Set the protocol switch 8 to
ON
.
Connect the
RX(+/-)
of the unit to the
RS-485(+/-)
port of the camera.
Match the camera’s address, baud rate, and protocol to the same to
those of the unit.
RS-232 device control supports SAMSUNG-E protocol only.
Connect the RS-232 device’s cable to the RS-232 port of the main unit.
Using RS-232 device, you can control the camera menu.
1.
2.
3.
4.
–
5.
6.
RS-232 and RS-485 communications cannot be used for simultaneous input.
For the switch settings, see the switch setting table. (See page 18)
Input of video signal is required to control RS-485.
NOTE
ADDRESS
(X)100
(X)10
(X)1
POWER
OFF
ON
CABLE
COMPENSATION
S
L
REMOTE CONTROLLER SCP-300
POWER
STATUS
TERMINATION
PROTOCOL
1
ON
2345678
1
ON
2