Description
Select Alarm
: This button is to choose output of alarm terminal you wish to setup.
When button is pressed: Appropriate alarm is selected
When button is not pressed: Appropriate alarm is not selected
Name
: Input name of alarm to use
Input Sensor No.
: If you want alarm to automatically operate from external sensor, input external sensor that’s
linked to alarm.
For example) If you wish to operate number 1 sensor when number 3 activates, choose
alarm 1 and input ”3” for following item.
Input Camera No.
: In order to activate external alarm by motion detection input the camera number that will
detect the movement.
Ex1.) If you want to activate alarm 1 on detecting movement on camera2 , select Alarm1
and input camera number “2”
Auto ON/OFF time(S)
: Input continuance of operating time for control output in second after sensor signaled.
(Possible to setup 1sec, 5sec, 10sec, 20sec, 30sec, 1min, 2min, 3min or manual mode.
Factory value is Manual mode.)
3-1
3-1
Hardware [Alarm]
Function
• It indicates whether alarm will be used or not and setup sensor and time of output produced.
• Output of alarm will be either ON/OFF when any sensor or moving(motion) object is captured.
It can control light, siren, speaker, and other external equipment.
Environment Setup