UTP Power Supply Hub
User Guide
8
UTP Power Supply Hub
User Guide
9
3-4. Connecting Peripheral Devices
4. Product Specifications
Model
SPU-400
Video Input Signal
Cable Link Only
Power
Input
AC 115/230 V 50/60 Hz
Output
24 VAC/28 VAC, 1 amp.
Optional Feature
24 VAC/Off/28 VAC switchable
Power On Display
Green
Protection
4 A Fuse
Maximum
Distance
(CAT. 5e UTP
Cable)
Camera Power
(SUB-2000 Camera)
24 VAC
300m
28 VAC
400m
Video/Data Signal
Cable link only
Connection Port
Video Input
4-Port (RJ-45 )
Video Output
1-Port (RJ-45)
Data
1-Port (RJ-45)
LED Display
Off
Not connected
Green
Load connected and working
Amber
Overload
Red
Short shutdown condition
Operating Temperature/Humidity
-10ºC ~+50ºC / 0 ~ 80%
Material/Weight
Steel/4kg
Dimension
260(W) x 44(H) x 225.2(D)
3. Product Parts and Peripheral Device Connection
Controller
SUB-2000
SUD-2080F
SPU-400
SMX-25632
SPU-400R
DVR
300m(1000ft) or less
900m(3000ft) or less
Rack Mount Instructions
1) Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly, the operating
ambient temperature of the rack environment may be greater than room ambient. Therefore,
consideration should be given to installing the equipment in an environment compatible with
the maximum ambient temperature (Tma) specified by the manufacturer.
2) Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of
air flow required for safe operation of the equipment is not compromised.
3) Mechanical Loading - Mounting of the equipment in the rack should be such that a hazardous
condition is not achieved due to uneven mechanical loading.
4) Circuit Overloading - Consideration should be given to the connection of the equipment to the
supply circuit and the effect that overloading of the circuits might have on overcurrent
protection and supply wiring. Appropriate consideration of equipment nameplate ratings
should be used when addressing this concern.
5) Reliable Earthing - Reliable earthing of rack-mounted equipment should be maintained.
Particular attention should be given to supply connections other than direct connections to the
branch circuit (e.g. use of power strips)."