16
Samsung Electronics
C. Load status display
1) When “power freezing” button and “power refrigeration” button are pressed for 5 seconds
during normal operation, it is activated by the refrigeration button while temperature setting
display repeats on/off 3 times.
2) Load which output of micom is displayed on LED.
3) Load status display maintains for 60 seconds and returns to normal operation.
No
1
2
3
4
5
6
7
8
9
10
11
Display LED
Freezer “LOW”
Freezer “LOW · M
e
d ”
Freezer “M
e
d”
Freezer “M
e
d · H I G H”
Refrigerator
“LOW · Med”
Refrigerator “Med”
Refrigerator
“M
e
d · HIGH”
Refrigerator “HIGH”
Quick Freezing
Quick Refrigeration
High humidity
refrigeration
Display
Relevant LED ON during comp
operation
Relevant LED ON during F-FAN
operation
Relevant LED ON during freezer
defrost heater on
Relevant LED ON during freezer
bulb ON
Relevant LED ON during F-FAN
operation
Relevant LED ON during
refrigerator defrost
Relevant LED ON during
refrigerator bulb ON
Relevant LED ON during
refrigerator brade rotation
Relevant LED ON with initial
power input
Relevant LED ON when ambient
temperature is over 35˚C
Relevant LED On when ambient
temperature is below 20˚C
Item
COMP
F-FAN
Freezer defrost Heater
Freezer bulb
R-FAN
Refrigerator defrost
Heater
Refrigerator bulb
GEARED-Motor
Initial Mode
Overload
Low temp.
Refrigerator Subordinate
Mode Display
Freezer Subordinate
(Load Status Display Table)