  Self-Test 

1. Make sure the paper roll has been installed properly. 
2. Turn on the power while holding down the FEED button. The self-test begins. 
3. The self-test prints the current printer status, providing the control ROM version and the 

DIP switch setting. 

4. After printing the current printer status, self-test printing will print the following, and 

pause. (The PAPER LED light blinks.). 

                

 Self-test printing. 

        Please press the FEED button 

5. Press the FEED button to continue printing. The printer prints a pattern using the built-in 

character set. 

6. The self-test automatically ends and cuts the paper after printing the following. 
        

      *** COMPLETED *** 

7. After the self-test is complete, the printer returns to normal on-line status. 

 

 Note 

The self-test lets you know if your printer is operating properly. It checks the print quality, 
ROM version, and DIP switch settings. 

 
 
 

  Specifications 

 

Item 

Details 

Printing Method 

Thermal Line Printing 

Dot Density 

SRP-350plus: 180 X 180 dpi (7dots/mm) 
SRP-352plus: 203 X 203 dpi (8dots/mm) 

Printing Width 

72mm 

Characters per line 
(Default) 

SRP-350plus: 42 (Font A) / 56 (Font B) 
SRP-352plus: 48 (Font A) / 64 (Font B) 

Printing Speed  *1) 

SRP-350plus: 47 lines/sec, 200 mm/sec 
SRP-352plus: 52 lines/sec, 195 mm/sec 

Receive Buffer Size 

4K Bytes 

SMPS Input Voltage 

100~240 VAC 

Frequency 50/60 

Hz 

SMPS Output Voltage 

24 VDC 

Temperature 

0 ~ 45 

 (Operating) 

-10 ~ 50 

 (Storage) 

Humidity 

30 ~ 80 % RH (Operating) 
10 ~ 90 % RH (Storage) 
; Except for paper 

Auto Cutter 

1,800,000 Cuts 

Printer 

Mechanism  MCBF *2) 70,000,000 

Lines 

Paper Type 

Paper Roll 

Roll Width 

80 mm 

Roll Diameter 

Max  83mm 

Paper Thickness 

0.062~0.075 mm 

Paper 

Paper Tube 

Inner: Ø12mm (0.47”) 
Outer: Ø18mm (0.71”) 

 

 Note

 

*1) Printing speed may be slower depending on the data transmission speed and the 

combination of control commands. 

*2) The above values are calculated under printing level 2 with recommended paper at 

normal temperature. 
The values may vary with environment temperature, printing level, etc. 

 
 
 

  Serial (RS-232C) Fixed Interface Model Windows Driver Installation: 

 IFA-S TYPE

 

1. After running the product installation CD, run the 

Thermal Printer > SRP-350plus > 

Drivers > Windows Driver > Drivers Folder >  Win SRP-350plus_Vx.x.x.exe

 file. 

2. In the opening installation window, click on 

Next

3. In the 

Ready to Install the Program

 window, click on 

Install

4. In the 

Select Port Type

 window, select one 

Serial Port 

and click 

Next

 

5. In the 

Question 

window, select Yes and the computer will reboot. 

6. After rebooting, open Start > Settings > Printers & Fax

 > BIXOLON SRP-350plus 

Icon > 

Right-Click > Properties. 

7. In the Properties window, select the Port tab and click on the Port Settings. Check to see 

that the information is identical to the self-test results after installation. 

 
 
 
 
 

 

8. In the Properties window, after selecting the General tab, click on Print Test Page to 

confirm that printing is normal 

 
 
 

  Parallel (IEEE1284) Fixed Interface Model Windows Driver Installation: 

IFG-P TYPE 

1. After running the product installation CD, run the 

Thermal Printer > SRP-350plus > 

Drivers > Windows Driver > Drivers Folder >  Win SRP-350plus_Vx.x.x.exe

 file. 

2. In the opening installation window, click on 

Next

3. In the 

Ready to Install the Program

 window, click on 

Install

4. In the 

Select Port Type

 window, select one 

Parallel Port 

and click 

Next

 (Refer to Figure 1.) 

5. In the 

Question 

window, select Yes and the computer will reboot. 

6. After rebooting, open Start > Settings > Printers & Fax

 > BIXOLON SRP-350plus 

Icon > 

Right-Click > Properties. 

7. In the

 Properties

 window, after selecting the General tab, click on Print Test Page to 

confirm that printing is normal. 

 
 
 

  USB Fixed Interface Model Windows Driver Installation: IFG-U TYPE 

1. After running the product installation CD, run the 

Thermal Printer > SRP-350plus > 

Drivers > Windows Driver > Drivers Folder > Win SRP-350plus_Vx.x.x.exe

 file. 

2. In the opening installation window, click on 

Next

3. In the 

Ready to Install the Program

 window, click on 

Install

4. In the 

Select Port Type

 window, select 

USB 

and click 

Next

. (Refer to Figure 1.) 

5-1. If using Windows 98/ME: 

 After completing the installation procedures, reboot the computer. 

 After rebooting, turn the printer power off and back on. 

 After the New Hardware Detected window appears, continue to click Next to install the 

USB

 drive, and then reboot the computer once more. 

5-2. If using Windows 2000: 

 

After the 

Information

 window appears, turn the printer off and back on and click Yes. 

 After installation is complete, reboot the computer.

 

5-3. If using Windows XP: 

 After the 

Information

 window appears, turn the printer off and back on and click Yes. 

 After the New Hardware Detected window appears, continue to click Next to install the 

USB

 drive, and then reboot the computer. 

 

 Note

 

When the digital registration message appears during installation, click on either 

OK

 or 

Continue Anyway

 
6. After rebooting, open Start > Settings > Printers & Fax

 > BIXOLON SRP-350plus 

Icon > 

Right-Click > Properties. 

7. In the Properties window, after selecting the General tab, click on Print Test Page to 

confirm that printing is normal. 

 
 
 

 

 Ethernet Fixed Interface Model Windows Driver Installation:  

IFA-E TYPE 

Refer to the user manual regarding separate Ethernet interface cards. (Refer to the CD.) 

 
 
 

 

 WEEE (Waste Electrical and Electric Equipment) 

 

This marking shown on the product or its literature, indicates that is should not be 
disposed with other household wastes at the end of its working life, To prevent 
possible harm to the environment or human health from uncontrolled waste disposal, 
please separate this from other types of wastes and recycle it responsibly to promote 
the sustainable reuse of material resources. Household users should contact either the 
retailer where they purchased this product, or their local government office, for details 
of where and how they can take this item for environmentally safe recycling. Business 
users should contact their supplier and check the terms and conditions of the purchase 
contract. This product should not be mixed with other commercial wastes for disposal.

 
 
 

  BIXOLON Co., Ltd. 

 

 Website

  http://www.samsungminiprinters.com 

 

 Headquarters 

(Add) A-502, Digital Empire, 980-3 Yeongtong-dong, Yeongtong-gu, Suwon-si, South Korea, 443-813 
(Tel) +82-31-218-5531 

 

 U.S. Office 

(Add) 1210 E. 223rd St., #330, Carson, CA 90745 
(Tel) +1-858 764 4581 

 

 Europe Office 

(Add) BIXOLON Europe GmbH, Lindenstrasse 169, 40233 Dusseldorf, Germany 
(Tel) +49 (0)211 68 78 54 0 

 
 

Summary of Contents for SRP-350 Bixolon

Page 1: ... Holding down the FEED button will discharge paper continuously until the button is released Setting the DIP Switches Changing Dip Switch settings must be done when the printer is off Any changes done while the printer is on will not be processed 1 Serial Interface DIP Switch 1 SW Function ON OFF Default 1 1 Auto Line Feed Enable Disable OFF 1 2 Handshaking XON XOFF DTR DSR OFF 1 3 Data Length 7bi...

Page 2: ...e opening installation window click on Next 3 In the Ready to Install the Program window click on Install 4 In the Select Port Type window select one Parallel Port and click Next Refer to Figure 1 5 In the Question window select Yes and the computer will reboot 6 After rebooting open Start Settings Printers Fax BIXOLON SRP 350plus Icon Right Click Properties 7 In the Properties window after select...

Page 3: ...sur le bouton ALIMENTATION jusqu à ce que tout le surplus du papier soit dégagé Paramétrage des commutateurs DIP La modification des paramètres des commutateurs DIP doit être effectuée lorsque l imprimante est éteinte Toute modification effectuée lorsque l imprimante est allumée ne sera pas traitée 1 Interface série Commutateur DIP 1 COM Fonction ON OFF Défaut 1 1 Saut de ligne automatique Activé ...

Page 4: ...in SRP 350plus_Vx x x exe 2 Dans la fenêtre de demande d installation cliquer sur Suivant 3 Dans la fenêtre Prêt à installer le programme cliquer sur Installer 4 Dans la fenêtre Sélectionner un type de port sélectionner un Port Parallèle puis cliquer sur Suivant Se reporter au schéma 1 5 Dans la fenêtre Question sélectionner Oui puis l ordinateur redémarrera 6 Après le redémarrage ouvrir Démarrer ...

Page 5: ...erruptor DIP 1 INT Función ENCENDIDO APAGADO Predeterminado 1 1 Alimentación de línea automática Activar Desactivar APAGADO 1 2 Entrada en comunicación XON XOFF DTR DSR APAGADO 1 3 Longitud de datos 7bits 8bits APAGADO 1 4 Control de paridad Sí No APAGADO 1 5 Selección de paridad PAR IMPAR APAGADO 1 6 APAGADO 1 7 ENCENDIDO 1 8 Selección de velocidad de transmisión bps Consulte la siguiente tabla 1...

Page 6: ...in SRP 350plus_Vx x x exe 2 En la ventana que se abra para la instalación haga clic en Siguiente 3 En la ventana Preparado para instalar el programa haga clic en Instalar 4 En la ventana Seleccione tipo de puerto seleccione un Puerto paralelo y haga clic en Siguiente Remítase a la figura 1 5 En la ventana Pregunta seleccione Sí y la computadora se reiniciará 6 Después de reiniciar vaya a Inicio Co...

Page 7: ...SACTIVADA Predefinição 1 1 Alimentação de linha automática Activar Desactivar DESACTIVADA 1 2 Sincronização XON XOFF DTR DSR DESACTIVADA 1 3 Extensão dos dados 7 bits 8 bits DESACTIVADA 1 4 Verificação da paridade Sim Não DESACTIVADA 1 5 Selecção da paridade UNIFORME ÍMPAR DESACTIVADA 1 6 DESACTIVADA 1 7 ACTIVADA 1 8 Selecção da velocidade de transferência bps Consulte a tabela 1 seguinte DESACTIV...

Page 8: ...e 3 Na janela Ready to Install the Program Pronto para instalar o programa clique em Install Instalar 4 Na janela Select Port Type Tipo de porta seleccionado seleccione uma Paralled Port Porta paralela e clique em Next Seguinte Consulte a figura 1 5 Na janela Question Pergunta seleccione Yes Sim e o computador reiniciará 6 Depois de reiniciar o computador abra Start Iniciar Settings Definições Pri...

Reviews: