INSTALLATION AND EXTERNAL CONNECTION
I/O CONNECTION
Input Connection
Connect the DC 12V(+) line of the power supply unit to the red line.
Connect the GND(-) line of the power supply unit to the black line.
- Exit Button Connection
Connect one end of the Exit button to the orange line.
Connect the other end of the Exit button to GND
- Door Contact Sensor Connection
Connect one end of the door contact sensor to the yellow with red stripes.
Connect the other end of the door contact sensor to GND.
- Auxiliary Input Device Connection (auxiliary input #1 – green, auxiliary input #2 – green with white stripes)
Connect one end of the auxiliary input device to auxiliary input #1 or auxiliary input #2.
Connect the other end of the auxiliary input device to GND.
1.
2.
1.
2.
1.
2.
1.
2.
1
3
2
6
5
4
7
9
8
ESC
0
ENT
F
1
F
2
F
3
F
4
F
5
F
6
F
7
F
8
F
9
F10
F11
F12
Mon 01 / 01 / 2010
10 : 30 : 20
183
"-.
%003
Door Contact Sensor: Yellow with the red stripe, GND
Exit Button: Orange line, GND
Connect 2.2K
to check for cut-off detection
Door Contact Sensor
Exit Button
Black -
Red +
GND
DC+12v
100V-220V
FG
L
N
Power
Supply