English
English
_ 41
USER MANAGEMENT
DOOR OPEN ALARM TIME SETUP
In this menu, you can set the delay time until the product triggers the door open alarm if the door stays open after the Door
Relay time. To use this function, the Door Contact sensor should have been installed on the entrance door. (see page 17)
The default is ‘03’.
Press the
F
2
SETUP MENU button.
Use the buttons
4
and
6
to move to the
OPEN ALR TIME
item and
press
ENT
.
Use the keypad to enter the time in two digits and press
ENT
.
00 : The alarm will sound shortly if the door stays open after the Door Relay
Time.
01~ 98 : The alarm will sound shortly if the door stays open after both of
Door Relay time and Door Delay alarm. (01~98 seconds)
99 : The Door Open alarm will not sound.
To use this function, the Door Contact sensor should have been installed on the entrance door.
ARM/DISARM
With the ARM/DISARM code active, you can set the ARM mode by entering the ARM code and presenting the card
(assigned Code 3 in registration) of a person who has the ARM/DISARM permissions. In this mode, all connected readers
will not take the card input any further. To release the ARM mode, enter the DISARM code and present the ARM/DISARM
card.
Press the
F
3
SETUP MENU button.
Use the buttons
4
and
6
to move to the
ARM/DISARM SET
item
and press
ENT
.
You are prompted to enter the ARM code.
Use the keypad to enter the ARM code in two digits and press
ENT
.
You are prompted to enter the DISARM code.
Use the keypad to enter the DISARM code in two digits and press
ENT
.
The Arm/Disarm code should be different from the Duress Mode password.
You can specify the output time for each signal out when ARM function is enabled.
(See Page 47 for “ARM/DISARM Output Setup”.)
1.
2.
3.
•
M
1.
2.
3.
4.
M
2.ARM/DISARM SET
00/00
ARM CODE
00
DISARM CODE
00
8.OPEN ALR TIME
03
8.OPEN ALR TIME
10