68_
additional features
additional features
INPUT TYPE SETUP
Either one of NO(00) or NC(01) is available for the input type.
The default setting is ‘00(Normal Open)’.
Press the
F
5
SETUP MENU button.
Use the buttons
4
and
6
to move to the
INPUT TYPE
item and
press
ENT
.
You can make input when the prompt blinks.
Use the numeric buttons to enter ‘00’ or ‘01’ for operation type for each
input and press
ENT
.
NO: Normal Open, open is normal
NC :Normal Close, close is normal
EX : Exit Button
DC : Door Open Sensor
I 1 : Aux Input #1
I 2 : Aux Input #2
TP : Tamper Input
If values other than ‘00’ or ‘01’ are entered, the error message of “INVALID NUMBER” will appear and the values you entered will
not be saved.
Check the operation type of the input device that is connected to the input port. If the operation type is set incorrectly, it will cause
unintended result.
1.
2.
3.
•
M
13.INPUT TYPE
0 0 : N O , 0 1 : N C
E X D C I 1 I 2 T P
0 0 0 0 0 0 0 0 0 0
13.INPUT TYPE
0 0 : N O , 0 1 : N C
E X D C I 1 I 2 T P
_ 0 0 0 0 0 0 0 0 0