User Guide

2

Maximum driver quantity per serial connection is limited. Using more quantity per run will cause overload from SMPS which 

damages all connected products. This will cause voltage drop and also dimmed lighting output.

CAUTION

Keep extension lead 

wires as short as possible.

Refer to below table for 

CONNECTION GUIDE

Power Supply

AC Input

DC Output

*Ensure that each run should have 25 modules 

 at max and should use another run in parallel to connect more

*When mixed run should occur, count 1(one) for C0230, C0320, and C0340

**Must count C0640 as 2(two) and keep the total counts under 50

Should use thicker wires which can take larger amount of current

than the amount transmitted from the power supply unit

STAR C0640

1st

25th

1st

1st

25th

1st

25th

1st

25th

80 mm

200 mm

400 mm

Use recommended length for pitch between each module to achieve optimum lighting output while maintaining lowest unit 

cost. Failure or misplacing will cause dimmed spots or uneven appearance of light on the surface.

LAYOUT DENSITY 

GUIDELINES

CONNECTION WITH 

POWER SUPPLY

Output (W)

Model Name

Recommended

Extension Wire

Output (A)

Maximum Length

30W

2.5A

PSGE-0030-12

5M (15FT)

VCTF1.25

AWG18

60W

5A

PSGE-0060-12

5M (15FT)

VCTF2.0

AWG14

120W

10A

PSGE-0120-12

5M (15FT)

VCTF2.0

AWG12

600W

50A

PSGE-0600-12**

15M (50FT)

VCTF5.5

AWG4

1000W

83A

PSGE-1000-12**

STAR C0640

19pcs

37pcs

73pcs

365pcs

610pcs

15M (50FT)

VCTF8.0

AWG2

EXTENSION OF POWER SUPPLY LEAD WIRES

**PSCS-0600-12, PSCS-1000-12 are not weather-proof

    Equip with protective box for outdoor use and the box should have ventilating holes

RECOMMENDED CENTER OF MODULE PITCH PER MINIMUM DEPTH

60 mm

70 mm

60 mm

80 mm

120 mm

180 mm

120 mm

300 mm

RECOMMENDED LAYOUT DENSITY PER CHANNEL WIDTH

0

4

6

0

C

0

4

3

0

C

0

2

3

0

C

0

3

2

0

C

  

FARD lighting GmbH     Seestrasse 20      D - 14974 Ludwigsfelde OT Genshagen

Tel. +49 - (0)3378 / 2003-0       Fax +49 - (0)3378 / 2003-29

info@fard-lighting.de       www.fard-lighting.de

Summary of Contents for STAR C0640

Page 1: ...s with sharp objects Put glue or silicon over the LED lamps PRECAUTIONS PREPARATION PREPARE CHANNELS 1 Clean moisture and dust inside 2 Make holes 3 Use bushing to protect wires 2 Make holes for wires from modules to SMPS 3 Without bushins wires will easily be cut and short circuit will occur SUPPLIES REQUIRED TOOLS REQUIRED Wire Nuts Cable Ties IDC Connectors VCTF PLTC Cable Optional Silicon and ...

Page 2: ...imum lighting output while maintaining lowest unit cost Failure or misplacing will cause dimmed spots or uneven appearance of light on the surface LAYOUT DENSITY GUIDELINES CONNECTION WITH POWER SUPPLY Output W Model Name Recommended Extension Wire Output A Maximum Length 30W 2 5A PSGE 0030 12 5M 15FT VCTF1 25 AWG18 60W 5A PSGE 0060 12 5M 15FT VCTF2 0 AWG14 120W 10A PSGE 0120 12 5M 15FT VCTF2 0 AW...

Page 3: ...34 6 22 34 41 1000 mm 1 DETERMINE LAYOUT Refer to LAYOUT DENSITY GUIDELINES on page 2 to determine spacing and amount of LEDs required SUPPORTS FOR OUR SIGNMATES Ask us to obtain accurate layout Stroke Width Channel Depth 2 PEEL AND STICK Using predetermined layout and LED placement from step 1 remove 3M tape on the back of modules attached on the surface CAUTION When handling the module avoid pre...

Page 4: ...dules that light and the modules that don t light Check this connection Beginning of a leg lights but the entire leg does not light or lights intermittently S LED is designed so if one module fails it will not cause the entire sign or leg to go out If one module does not light but all others in the leg do replace this module with a new one One module does not light but all others in the leg light ...