Maximum driver quantity per serial connection is limited. Using more quantity per run will cause overload from SMPS which
damages all connected products. This will cause voltage drop and also dimmed lighting output.
CAUTION
Keep extension lead
wires as short as possible.
Refer to below table for
CONNECTION GUIDE
Power Supply
AC Input
DC Output
*Ensure that each run should have 25 modules
at max and should use another run in parallel to connect more
*When mixed run should occur, count 1(one) for C0230, C0320, and C0340
**Must count C0640 as 2(two) and keep the total counts under 50
Should use thicker wires which can take larger amount of current
than the amount transmitted from the power supply unit
STAR C0640
1st
25th
1st
1st
25th
1st
25th
1st
25th
80 mm
200 mm
400 mm
Use recommended length for pitch between each module to achieve optimum lighting output while maintaining lowest unit
cost. Failure or misplacing will cause dimmed spots or uneven appearance of light on the surface.
LAYOUT DENSITY
GUIDELINES
CONNECTION WITH
POWER SUPPLY
Output (W)
Model Name
Recommended
Extension Wire
Output (A)
Maximum Length
30W
2.5A
PSGE-0030-12
5M (15FT)
VCTF1.25
AWG18
60W
5A
PSGE-0060-12
5M (15FT)
VCTF2.0
AWG14
120W
10A
PSGE-0120-12
5M (15FT)
VCTF2.0
AWG12
600W
50A
PSGE-0600-12**
15M (50FT)
VCTF5.5
AWG4
1000W
83A
PSGE-1000-12**
STAR C0640
19pcs
37pcs
73pcs
365pcs
610pcs
15M (50FT)
VCTF8.0
AWG2
EXTENSION OF POWER SUPPLY LEAD WIRES
**PSCS-0600-12, PSCS-1000-12 are not weather-proof
Equip with protective box for outdoor use and the box should have ventilating holes
RECOMMENDED CENTER OF MODULE PITCH PER MINIMUM DEPTH
60 mm
70 mm
60 mm
80 mm
120 mm
180 mm
120 mm
300 mm
RECOMMENDED LAYOUT DENSITY PER CHANNEL WIDTH
0
4
6
0
C
0
4
3
0
C
0
2
3
0
C
0
3
2
0
C